Specifications; Figure 2. Csa Deployment Guidelines; Table 5. Led Operation During Standard; Enhanced Loopbacks - ADTRAN 239 HR Installation And Maintenance Manual

High-bit-rate digital subscriber line range extender
Table of Contents

Advertisement

Table 5. LED Operation During Standard/Enhanced Loopbacks
LED
Standard Operation:
NET LP1 and LP2 .... Both of these LEDs will remain solid when an HRE network loopback is active.
CUST LP1 and LP2 . Both of these LEDs will go Off when an HRE network loopback is enabled, and will come
LL/RL ....................... This LED will be yellow when an HRE network (local) loopback is active. HRE customer
Enhanced Operation:
NET LP1 and LP2 .... Both of these LEDs will remain solid when an HRE network or customer loopback is active.
CUST LP1 and LP2 . Both of these LEDs will remain solid when an HRE network or customer loopback is active.
LL/RL ....................... This LED will be yellow when an HRE network (local) loopback is active. The LED will be
12
11
INVALID CSA CABLE LENGTHS
10
9
8
7
6
5
4
3
2
VALID CSA CABLE LENGTHS
1
0
0
1
2
WORKING LENGTH OF 26 GAUGE CABLE (KFT)

Figure 2. CSA Deployment Guidelines

6
Descriptions and Indications
back On after the unit has synchronized with the HTU-C.
(remote) loopback is not available when using Standard Loopback code.
green when an HRE customer (remote) loopback is active.
TOTAL
BRIDGED
2.5
2.0
TAP
1.5
LENGTH
1.0
0.5
(KFT)
0.0
3
4
5
6
7
8
Section 61246045L1-5, Issue 2

Table 6. Loop Insertion Loss Data

Frequency (Hz)
3000 .....................................12.0
10,000..................................15.0
50,000..................................25.5
100,000................................30.0
150,000................................32.75
200,000................................35.25
Performance monitoring, diagnostics, and loopbacks
are also available from the craft interface at the
HTU-C and HTU-R.
When testing indicates a faulty circuit pack, refer to
the housing installation/maintenance practice for the
entry and pressurization control, then replace the
faulty circuit pack.
An in-band loopback test can be performed from the
9
central office (see Appendix A of this practice).
ADTRAN does not recommend field repair of this
unit. Repair services may be obtained by returning
the defective unit to the ADTRAN Customer and
Product Support (CAPS) Department.

6. SPECIFICATIONS

Specifications for the ADTRAN 239 HRE are
detailed in Table 7.