Installation; Table 1. Telecommunications Codes - ADTRAN 239 HR Installation And Maintenance Manual

High-bit-rate digital subscriber line range extender
Table of Contents

Advertisement

Part Number Unit Name
1242002LX ..... 220/E220 HTU-C
1242016LX ..... 3192 HTU-C
1242023LX ..... DDM Plus HTU-C
1244001LX ..... 4th Generation 220/E220
1244021LX ..... 4th Generation T400 HTU-R
1244022LX ..... 4th Generation T400 HTU-R
1245001LX ..... 5th Generation 220/E220
1245021LX ..... 5th Generation T200 HTU-R
1245022LX ..... 5th Generation T200 HTU-R
1245003LX ..... 5th Generation DDM and
1245004LX ..... 5th Generation 3192 HTU-C
1245026LX ..... 5th Generation T200 HTU-R
1245002LX ..... Litespan AHT1U
1245024LX ..... T400 HTU-R
1246001LX......6
1246003LX......6
1246004LX......6
1246026LX......6
There are no manual option settings on the HRE.
HRE operating power is derived from an HTU-C,
independent of line impedance or wire gauge. The
operating power from the HTU-C is also used to
span power the Low Voltage HTU-R.
The HRE operates at line losses up to 35 dB at 196
kHz, in both directions from the extender and
regenerates the 2B1Q signals to meet the
transmitted power spectrum of Bellcore
TA-NWT-0001210.
Revision History
This revision is provided to correct Table 4. LED
Indicators.

2. INSTALLATION

C A U T I O N !
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
2
HTU-C
CP
SA
HTU-C
CP
SA
HTU-C
th
Generation 220/E220 HTU-C
th
Generation DDM+ HTU-C
th
Generation 3192 HTU-C
th
Generation T200 HTU-R
Section 61246045L1-5, Issue 2
Remove the ADTRAN 239 HRE from the carton
and visually ensure that damage has not occurred
during shipping or handling. If damage has
occurred, file a claim with the carrier, then contact
ADTRAN. See Warranty and Customer Service
(subsection 7 of this practice).
The ADTRAN 239 HRE is shipped in a separate
carton and must be installed in an environmental
apparatus case.
Electrical Code Compliance
Table 1 shows the Telecommunications Codes for
the 239 HRE. The 239 HRE complies with the
requirements covered under UL 1950 third edition
and is intended to be installed in an enclosure with
an Installation Code (IC) of "B" or "E."
NOTE:
This product is intended for installation in
Restricted Access Locations only.

Table 1. Telecommunications Codes

Code Input Output
IC
A
-
TC
X
X
PC
C
C
When installing the ADTRAN 239 HRE, refer to
the ADTRAN Installation/Maintenance practice for
the housing being used.
All connections are made through card edge
connectors. Table 2 gives the card edge pin
assingments.
NOTE:
Ensure that the chassis groungd is securly
connected to apparatus case. Ground pin
designations are defined in Table 2.
The ADTRAN 239 HRE is designed for installation
in a prewired apparatus case, and the capacity
guidlines for deployment are defined in Table 3.
61246045L1-5B