Mid approved sgs.uk appendix b and d, measures kwh, kvarh, kvar,pf,hz, max demand, rs 485 modbus autometers v6 protocol, two pulse outputs, bi- directional measurement for import and export, back light lcd for full viewing angles, available as 1 phase 2 w (17 pages)
1. Black locking bezel 2. Main meter case 3. Top terminal cover 4. Lower terminal cover Overview The IC7-C and IC9-C meter is 230/400 volt 50 Hz, 5 amp current transformer operated meter designed for measuring 3 phases Diagram 1. Meter Installation in a 4 wire star configured system back of the meter.
Wiring information continue going through the Power supply numbers until the number you 3P4W 230 / 400V 50HZ The standard IC9 requires a 230 require reappears. Stop at your CT Rat i o ****:5 volt 50 Hz supply. This is powered correct number '1'.
Screen Definitions e) Energy Page 4 I MPORT ENERGY HARMON I C *** ( % ) Below are the available screens, = 000000.00 35 th= 0 .00 43t h=0.00 which can be seen by pressing KVAH = 000000.00 37 t h=0 .00 45t h=0.00 the various keys on the front of KVARH = 000000.00 39 t h=0 .00 47t h=0.00...
Page 5
viii. Press 'ENTER' Key 2) Function operating display: To see meter information Press 'FUNCT' key. Display will continually press to scroll down change to below. pages. PLEASE ENTER Page 1 FUNCT I ON NUMBER AUTOMETERS LTD I C9 SER I AL N o : 900000 1 ADDRESS : 00 On the screen above, you will see two asterix, one flashing.
Page 6
RESET MAXIMUM DEMAND CURRENT TRANSFORMER PULSE TEST Function 12. AND VOLTAGE CONNECTION Function 60 SETTINGS RELAY PULSE TEST Function 50 PRESS ENTER KEY PULSE EVERY SECOND CONNECT I ON TO R ESET MD L 1 i mpo r t V 1 OFF PRESS ENTER TO EX I T L2 i mpo r t V2 OFF...
Page 7
Wiring Information TOP SWITCH Power Supply MODBUS The standard IC7-C and IC9-C ADDRESS requires a 230 volt, 50Hz supply. This is provided from the L3 phase and Neutral internally. LOWER SWITCH Wiring MODBUS Electrical and communication PARAMETERS connections are made to...
Page 8
Performance and data Overview Current transformer selection The IC7-C and IC9-C meters are 230/400 volt 50 Hz, 5 amp For accurate monitoring, correct selection current transformer operated meter designed for measuring of the current transformers is critical. 3 phases in a 4 wire star configured system and is...