Measuring Level and Base Flatness:
1. Make sure your surfaces are clean and free of debris.
2. Inspect the base mountings for proper bolting, surface deformation, bending,
cracking, soft foot failed concrete or grouting, etc.
3. The B.A.T. should be placed flat on the base or surface to be measured. If the
surface area is too small you may use the GlowLine® targets affixed to the B.A.T. or
fabricate "standoff blocks" for your application.
4. Place the B.A.T. laser o n one corner or location of the measured area.
5. Place the other B. A. T. or the GlowLine® targets on opposing locations.
6. FLATNESS ONLY CONDITION: Observe the vial and the GlowLine® targets,
if the vial is out of the "Bull Eye" but the laser is on the center white line on the
GlowLine® targets. The base is flat but NOT level. This condition MAY or MAY
NOT be satisfactory.
7. LEVEL AND FLAT CONDITION: Observe the vial and if the vial is in the "Bulls
Eye" and the laser is on the center white line on the GlowLine® targets, the base is
flat AND level.