In case Alfa control panel is connected to the heat recovery unit, the following operational information is displayed on the control
panel:
start of heating within the heating circuit
temperature setpoint of the heating circuit
the set heating mode (manual mode, time schedule, vacation mode)
cloud connection status ("Cloud" symbol is displayed in case both the heat recovery unit and the boiler are connected)
heating water temperature (if available)
outdoor temperature
boiler error alerts
In case CoolBre e z e
CoolBre e z e is connected to the system and the boiler switches from the "AUTO" mode into the "COLD" mode, the
CoolBreeze switches into heating mode automatically. In case the boiler is heating and the CoolBreeze cooling mode is turned
on, the Sim ultane ous he ating and cooling
Sim ultane ous he ating and cooling error alert is displayed. In case of joint operation wall-mounted control panel of
the boiler does not have to be installed in the reference room, as the information about temperature is ignored by the boiler; the
heat recovery unit provides boiler with information on average temperature from all control panels within the house. In this case
control panel of the boiler should be installed as close to the boiler as possible for convenient servicing.