    TABLE OF CONTENTS Introduction ....................................2 1. Identification and application ............................2 2. Safety instructions................................3 3. Heat recovery operation principle ..........................3 4. Structural parts of the heat recovery unit ......................4 4.1. Unit body .............................................4 4.2. LED backlight .............................................4 4.3. Filters and filter replacement ....................................4 4.4.
  • Page 4: Introduction

    Introduction The User Manual deals with the Futura heat recovery system, which is designed for controlled ventilation and treatment of the indoor environment of residential premises. The heat recovery system ensures recovery of heat and humidity, filters supplied air, helps maintain optimum humidity and provides after-cooling by means of an integrated automatic by-pass in summer, in the night mode.
  • Page 5: Safety Instructions

    2. Safety instructions Always follow the safety instructions that are included in the User Manual. Failure to observe them may result in personal injury or damage of the heat recovery system. (1) The equipment has been developed and produced to provide controlled ventilation in residential buildings and premises. (2) The equipment may only be used for purposes for which it has been developed and produced and for which it has adequate technical capabilities –...
  • Page 6: Structural Parts Of The Heat Recovery Unit

    4. Structural parts of the heat recovery unit The heat recovery unit consists of the following structural parts: Ambient air Waste air Fresh air Indoor air Supply filter Exhaust filter Power inlet and fuse Connectors Pwr Board Main board Bypass servo Power supply Waste Fresh...
  • Page 7: Obr. 4 Button Of Initialization Of New Filters

    Users are alerted to the need to replace filters by: a) a change of the colored LED backlight on the front side of the unit (see page 4, Tab. 2 – Colored LED backlight), b) a message in the MyCOMPANY application. Indication of a clogged filter: Filter The heat recovery system must not be used without filters! During the replacement of filters and any mainte- nance activity, the unit must be off!
  • Page 8: Enthalpy Exchanger

    Clogged filters that are not replaced regularly can cause higher pressure losses, poor air flow, settling of dust on the fan blades, which changes their characteristic, higher power consumption and higher power of the fan motors. This results in excessive wear, imbalance of the system and generally improper operation of the heat recovery system.
  • Page 9: Icing Protection

    Thanks to the connection Stand-by to the Jablotron Cloud, the heat recovery unit can be activated and its settings can be changed any time. In the Stand-by mode the unit responds to the Boost function.
  • Page 10: Functions Of The Heat Recovery System

    6. Functions of the heat recovery system The heat recovery unit works in certain modes and functions whose activation and start is accompanied by lighting up of the respective symbol. The following functions of the heat recovery unit are distinguished: Boost (forced ventilation) A top power (5) function used if fast, forced ventilation of the indoor premises is required.
  • Page 11: Control Of The Heat Recovery System

    7. Control of the heat recovery system The control of the heat recovery system has been designed with the aim of easy operation and at the same time clear and intuitive indication of the current status. The heat recovery system can be controlled locally as well as remotely. 7.1.
  • Page 12: Optional Accessories

    You can rotate the switch to change the operation mode of the heat recovery unit (see page 7, 5. Operation Modes) in the sequence: Constant Power 1 - 2 - 3 - 4 - 5 Automatic Mode Fig. 8 – Changing the operation mode Turning of the switch will terminate the Boost, Night Mode, Party and Circulation functions.
  • Page 13: Guarantee

    5 years from the moment of commissioning by a certified installation partner, b) during another 2 years if the customer uses an alarm and the service of the Jablotron Security Center throughout the guarantee period. (2) The guarantee does not cover the costs related to possible disassembly and reassembly of a defective product.
  • Page 14: Appendices

    Appendices Appendix 1 Control – dimensions...