jablotron FUTURA User Manual

jablotron FUTURA User Manual

Ventilation unit with heat and moisture recovery
Hide thumbs Also See for FUTURA:

Advertisement

Quick Links

Ventilation unit
with heat and moisture recovery
FUTURA
User manual

Advertisement

Table of Contents
loading

Summary of Contents for jablotron FUTURA

  • Page 1 Ventilation unit with heat and moisture recovery FUTURA User manual...
  • Page 3: Table Of Contents

    13. Functions, priorities and their response to simultaneous activation 8. Controlling the unit with Alfa control panel 1. Home screen 2. Quick access 3. Futura quick access screens 4. CoolBreeze quick access screen 5. Settings quick access screen 6. Error notifications on home screen 9.
  • Page 4 1. Login and basic control 2. Information about the unit 3. Advanced settings 4. Setting the Time schedule mode 4. Sharing access to Futura 11. Warranty 12. Disposal 1. Information for users regarding the disposal of electrical and electronic appliances (households) 2.
  • Page 5 Introduction Subject of this installation manual is Futura - ve ntilation unit w ith he at and m ois ture re cove ry Futura - ve ntilation unit w ith he at and m ois ture re cove ry, which is designed for controlled ventilation and treatment of the indoor environment of residential premises.
  • Page 6 JABLOTRON FUTURA USER MANUAL 3 3 . . Safety instructions Safety instructions Always follow the safety instructions that are included in this User Manual. Failure to observe them may result in personal injury or damage of the heat recovery unit.
  • Page 7 JABLOTRON FUTURA USER MANUAL 4 4 . . Heat recovery operation principle Heat recovery operation principle The heat recovery system ensures continuous replacement of used air with fresh, clean air. Heat recovery takes place in the exchanger, where the supplied air receives part of heat and humidity from extracted air (mainly from kitchen, bathroom etc.).
  • Page 8 JABLOTRON FUTURA USER MANUAL 5 5 . . Structural parts of the heat recovery unit Structural parts of the heat recovery unit The heat recovery unit consists of the following structural parts: Figure 3 – Unit structure A - Outdoor air...
  • Page 9: Led Indicator

    JABLOTRON FUTURA USER MANUAL 5 5 . . 2 2 . . LED indicator LED indicator LED indicator is located on the front cover of the unit. It provides a visual indication of unit's current status. During normal operation green light pulses in regular intervals. A change in the LED color indicates an error notification, need to replace filters or Bluetooth activation.
  • Page 10: Fans

    5 5 . . 5 5 . . Fans Fans Futura heat recovery unit contains two efficient fans with an integrated electronic unit and the function of maintaining a constant 8/29 JABLOTRON LIVING TECHNOLOGY...
  • Page 11: Summer Bypass

    When the heat recovery unit is in Stand-by mode, the air exchange is not active. Information from all the connected sensors is available, being continuously evaluated. Thanks to connection to Jablotron Cloud, the heat recovery unit can be activated and its settings can be changed any time.
  • Page 12 JABLOTRON FUTURA USER MANUAL cooler summer nights. This prevents the warm exhausted air from transferring the unwanted heat to the colder air from the outside and heating it up 7 7 . . 3 3 . . Night mode Night mode A reduced power function used at night.
  • Page 13: Boost (Forced Ventilation)

    JABLOTRON FUTURA USER MANUAL Cooling permission Automatic bypass permission The following functions are deactivated after restart: Boost Circulation Overpressure Night mode Party Drying Filter check Shutdown Servicing mode Bluetooth permission 7 7 . . 11 11. . Winter operation Winter operation Winter operation is started automatically when the average temperature of exhausted air drops below -3 °C (27 °F).
  • Page 14: Icing Protection

    JABLOTRON FUTURA USER MANUAL 7.12.4. Icing protection Icing protection is activated when the average temperature of the exhausted air is below -3 °C. Icing protection blocks Time schedule mode, Auto mode (in case the unit is controlled by CO sensors) or analogue voltage input from stopping the fans.
  • Page 15 8 8 . . Controlling the unit with Alfa control panel Controlling the unit with Alfa control panel Alfa control panel is a standard joint control panel for Jablotron Living Technology systems. Its operation starts on home screen. 8 8 . . 1 1 . . Home screen Home screen Figure 6 –...
  • Page 16: Home Screen

    JABLOTRON FUTURA USER MANUAL level, depending on the setting). After three seconds of inactivity the value is saved and the secondary quick access indication disappears from home screen. Dis playing s ubs ys te m value s Dis playing s ubs ys te m value s If a subsystem is available, its current value with respective unit is displayed below its icon.
  • Page 17 JABLOTRON FUTURA USER MANUAL displayed when the subsystem is connected. Scrolling through ite m s Scrolling through ite m s Unless the subsystem is in the Stand-by state, “Operating Mode” is highlighted by default when entering the Quick Access screen. The currently highlighted item is indicated by a bold black frame. If the item's value can be changed, small arrows appear above and below the item.
  • Page 18 JABLOTRON FUTURA USER MANUAL Figure 9 – Adjusting the value of selected item 8 8 . . 3 3 . . Futura quick access screens Futura quick access screens Futura has three basic quick access screens. Their description is stated below.
  • Page 19 JABLOTRON FUTURA USER MANUAL Figure 11 – Second quick access screen Circulation. Circulation. Click to display the Time Setting Screen (Quick Access). The icon shows whether the Circulation function is active. If active, the Circulation icon is displayed along with remaining time (HH:MM). If the Circulation function is not active, only the circulation icon is displayed.
  • Page 20: Coolbreeze Quick Access Screen

    Scrolling through CoolBre e z e m e nu The logic of scrolling through CoolBreeze menu is the same as scrolling through the quick access of Futura. Turning the dial clockwise moves the highlight in the following order: "Set temperature", "Back", "Stand-by" and again "Operating mode". The "CoolBreeze power indication"...
  • Page 21: Settings Quick Access Screen

    Scrolling through Se ttings ite m s The logic of scrolling through settings items is the same as for Futura quick access. Turning the dial clockwise moves the highlight in the following order: "Temperature unit °C/°F", "Back", and again "Primary Quick Access". Turn the dial counter- clockwise to scroll the items in the reverse order.
  • Page 22 JABLOTRON FUTURA USER MANUAL 8 8 . . 6 6 . . Error notifications on home screen Error notifications on home screen If an error or warning arises in any of the subsystems, the home page header will dim and display an exclamation mark icon. In case of an error LED indicator turns red and flashes at maximum intensity;...
  • Page 23 Outdoor unit starts defrosting automatically. CoolBreeze enters cooling mode during defrosting and removes indoor air heat. Futura temporarily turns on its internal heating to 100 % during defrosting to at least partially compensate for cooling of indoor air. Fan speed does not change.
  • Page 24 10.3.1. Login and basic control Sign in to MyJABLOTRON. After sign-in, you will see a list of all of your installed JABLOTRON devices. You can access device settings (Futura or CoolBreeze in this case) by tapping on its respective icon.
  • Page 25 JABLOTRON FUTURA USER MANUAL At the same time, you can read current information regarding the unit (mode, status, fan speed), current temperature, humidity, concentration and Boos t, Circulation and Ove rpre s s ure Boos t, Circulation and Ove rpre s s ure settings as described above (see chapter Functions of heat recovery unit).
  • Page 26 JABLOTRON FUTURA USER MANUAL Third screen contains information about flow rates assigned to each ventilation level (this is set by HVAC technician during installation - the user cannot adjust this setting), current power consumption and status of unit actuators. The last screen contains your HVAC technician's and our customer support contact information.
  • Page 27 JABLOTRON FUTURA USER MANUAL In G RAPH S G RAPH S section, you can access graphic information about peripherals, such as CO concentration from CO sensor. Tap on the three dots in the upper right corner to access expanded selection menu for graphs from other sensors.
  • Page 28 JABLOTRON FUTURA USER MANUAL De vice Se ttings tab allows you to rename your unit, set up information sharing with your HVAC technician, turn Radon De vice Se ttings Radon prote ction mode on or off, initiate filter change or reset the unit.
  • Page 29 USER MANUAL 10 10. . 4 4 . . Sharing access to Futura Sharing access to Futura Sharing menu allows you to configure how you share access to Futura with other users along with different levels of their Sharing access rights.
  • Page 30 11 11. . Warranty Warranty Futura heat recovery unit is covered by an extended warranty of 5 years. The warranty period begins once the unit is commissioned by a certified installation partner. Acknowledgment of warranty claims is subject to compliance with all instructions given in the User Manual, which is part of the delivery.
  • Page 31 JABLOTRON FUTURA USER MANUAL 12 12. . Disposal Disposal 12 12. . 1 1 . . Information for users regarding the disposal of electrical and Information for users regarding the disposal of electrical and electronic appliances (households) electronic appliances (households) Figure 35 –...

Table of Contents