Initial Power-Up - Bryant Evolution Control SYSTXBBUID01 Installation And Start-Up Instructions Manual

Table of Contents

Advertisement

Variable-Speed
Furnace/Fan Coil
User Interface
Green
A
Yellow
B
White
C
Red
D
S1
Optional Remote
Room Sensor
S2
Humidifier
Connection
Fig. 13—Connection Diagram for
Furnace or FE Fan Coil w/1-Spd. AC
Variable-Speed
Fan Coil
User Interface
Green
A
Yellow
B
White
C
Red
D
S1
Optional Remote
Room Sensor
S2
Humidifier
Connection
Fig. 14—Connection Diagram for
FE Fan Coil w/1-Spd. HP
WARNING:
FIRE OR EQUIPMENT HAZARD
Failure to follow this warning could result in equipment
damage or fire.
Do not apply 24vac fan powered humidifier (with internal
power supply) direct to indoor unit HUM and COM
terminals.

INITIAL POWER-UP

NOTE: Refer to Functional Overview (Fig. 11) to become
familiar with key function buttons such as "System On/Off",
"Fan", "Left-Side" and "Right-Side" buttons, etc. These function
buttons will be used frequently during setup.
A. Section 1 — Power Up Sequence
This section addresses initial power up (or commissioning) of a
new Evolution Control™. The User Interface will communicate
and identify all Evolution components in the system. The follow-
ing is a typical example for a communicating Variable-Speed
Furnace / Fan Coil with a 2-spd. Air Conditioner / Heat Pump
(including Dual Fuel).
A
B
ABCD
C
Connection
D
1-Spd. AC
HUM
COM
C
24V
Y
Y/Y2
OAT
OAT
Sensor
A03147
A
B
ABCD
C
Connection
D
1-Spd. HP
HUM
C
C
R
R
O
O
W
W2
Y
Y
OAT
OAT
Sensor
A03148
The User Interface display will light up and indicate that it is now
"ESTABLISHING COMMUNICATIONS WITH EQUIPMENT
PLEASE WAIT". The User Interface will automatically continue
by "SEARCHING FOR INDOOR EQUIPMENT", followed by
"SEARCHING FOR OUTDOOR EQUIPMENT" (See Figure 15).
Once the indoor and outdoor equipment has been found, the
Installer will be asked to select Accessories. Proceed to Section 4.
Selecting Accessories.
NOTE: If the variable-speed indoor equipment (furnace or fan
coil) cannot be found, the User Interface will display "CANNOT
COMMUNICATE WITH INDOOR UNIT". This MUST be
corrected before the initial power up sequence can continue. If
indoor unit is found, but the outdoor unit is not found, "OUT-
DOOR UNIT NOT IDENTIFIED" will appear. Proceed to the next
section for Outdoor Unit Identification.
ESTABLISHING
COMMUNICATIONS
WITH EQUIPMENT
PLEASE WAIT
SOFTWARE
VERSION
Fig. 15 — Power Up Sequence
B. Section 2 — Selecting Outdoor Unit
If there is no communicating outdoor unit, the screen, shown in
Fig. 16, will appear. Press either Time or Temp +/- buttons to
select AC (air conditioner), HP (heat pump), or None (no unit
installed). Press the right-side button to continue to the next screen.
If you have selected either AC or HP as the outdoor unit type, the
following middle screen will appear (See figure 16). Press either
Time or Temp +/- buttons to select appropriate Btu size of outdoor
unit, then press right side button to continue. If a NIM (Network
Interface Module) is applied for non-communicating two-speed
outdoor equipment, select 1 or 2speed compressor operation , and
press right-side button to continue.
NOTE: Range of Btu selection is limited by the model number of
the indoor unit installed. The Evolution Control™ will not allow
an outdoor unit size that is not supported by the installed indoor
OUTDOOR UNIT
NOT IDENTIFIED
SELECT TYPE:
NONE
NONE, AC, HP
PRESS +/- TO MAKE
SELECTION
CONTINUE
Fig. 16—Selecting Outdoor Unit
unit.
NOTE: On new system installations, the model and serial number
will be recognized and displayed. On any indoor/outdoor board
replacements, the equipment will be recognized but the exact
model/serial number will not be displayed.
—5—
INDOOR UNIT
OUTDOOR UNIT
SEARCHING FOR
SEARCHING FOR
INDOOR EQUIPMENT
OUTDOOR EQUIPMENT
WORKING
WORKING
OUTDOOR UNIT
OUTDOOR UNIT
ENTER HEAT PUMP
HEAT PUMP
SIZE
36000 BTU
ENTER NUMBER OF
SPEEDS, 1 or 2:
18000 TO 60000 BTU
PRESS +/- TO MAKE
PRESS +/- TO MAKE
SELECTION
SELECTION
BACK
CONTINUE
BACK
A03195
1
CONTINUE
A03196

Hide quick links: