Download Print this page

My Fireplace Blower FBK-250 Instructions

Blower kit with cord set

Advertisement

Quick Links

MY
FireplaceBlower
High Quality Aftermarket Fireplace Blowers & Fans
Instructions for FBK-250 Blower Kit with Cord Set
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Drywall dust or other fragments may be present in your fireplace's vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner's Installation Manual for your particular model number
for Supplemental Information before starting installation. This Blower Kit may be used with gas fireplaces.
Blower Kit Parts
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Description
Fan
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set
Wire Nut
Mounting Bracket for Fan
Dampening Pad, Velcro Strip
Crimp Butt Connector for Wire
Face Plate for Wall
Installation Instructions
Step 1: Turn Off Fireplace and allow it to cool
down. Disconnect from 120V Power. Shut off
the Gas supply. Remove the louver which cov-
ers the lower vent space below the firebox.
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
fireplace.
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2015
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
Qty.
1
1
1
1
2
1
2
1
1
1
(Downloadable)
NOTE: Diagrams and Illustrations NOT to Scale
MyFireplaceBlower.com:
Step 2: Push the Green Ground Wire disconnect onto
the ground tab on the end of fan. (Figure: 1)
Connect white and black wires of the cord set to ei-
ther of the two spade terminals attached to the motor.
Push disconnects onto metal tabs.
(Figure: 1)
Figure: 1
Page 1 of 5
Installation Videos:
Installation Instructions:
1-800-466-4045
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
CL ICK
CL ICK
CL ICK

Advertisement

loading
Need help?

Need help?

Do you have a question about the FBK-250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for My Fireplace Blower FBK-250

  • Page 1 MyFireplaceBlower.com: CL ICK 1-800-466-4045 High Quality Aftermarket Fireplace Blowers & Fans Instructions for FBK-250 Blower Kit with Cord Set WARNING RISK OF FIRE AND ELECTRICAL SHOCK! TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER! When installed, make sure to contain any excess wire of the cord set;...
  • Page 2 90°F. Dampening Pad Figure: 5 My Fireplace Blower Installer is responsible to check local codes NOTE: Diagrams and Illustrations NOT to Scale and read all instructions prior to installation. Burlington, Wisconsin Page 2 of 5 Layout designed in U.S.A.
  • Page 3 WHITE BLACK BLACK Figure: 7 Thermodisc/ Variable Optional Thermostatic Switch My Fireplace Blower Installer is responsible to check local codes NOTE: Diagrams and Illustrations NOT to Scale Heat Sensor Speed Control and read all instructions prior to installation. Burlington, Wisconsin Page 3 of 5 Layout designed in U.S.A.
  • Page 4 Figure: 9 Cut Here My Fireplace Blower LLC produces and sells aftermarket fireplace blower kits; which require consultation of an Owner’s Installation Manual from the Manufacturer of a particular fireplace model number for in- stallation. During Installation of a fireplace blower kit or replacement blower, refer to the Owner’s Instal- lation Manual for your particular fireplace model to obtain supplemental information.
  • Page 5 This will firmly hold both screw driver. wires in place. (Figure:11) •Go back to Step 3. Figure: 11 My Fireplace Blower Installer is responsible to check local codes NOTE: Diagrams and Illustrations NOT to Scale and read all instructions prior to installation. Burlington, Wisconsin Page 5 of 5 Layout designed in U.S.A.