The chimney must be designed according to the technical data of the stove (Technical data in
this manual).
The horizontal length of the flue pipe should not exceed 2.5 m.
The flue pipe must have no more than three 90° elbows. Each elbow should have a tight cleaning
aperture.
The chimney must be resistant to condensation.
To ensure your pellet stove operates correctly, a chimney draught of 3 Pa - 12 Pa is stipulated.
Austroflamm pellet stoves are approved by the manufacturer for chimneys with multiple occu-
pancy. In such a case, national, regional and local regulations must be complied with.