  • Page 1 Benutzerhandbuch / user instructions/ Istruzioni per l’uso / manuel d’instructions Mo Duo / Clou Duo...
  • Page 3: Table Of Contents

    Initial Operation, Using the Stove ....................4 3.1. Operating the stove via touch display ..................... 4 3.2. User control of the stove by means of the AUSTROFLAMM control knob ........12 3.3. Operating the stove using the IR remote control ................13 3.4.
  • Page 4: Important Information For The Stove User

    english 1. Important information for the Stove User • The information in this manual is of a general nature. National and European standards, local and building regulations, and fire safety provisions must be observed. • Please read this manual carefully before installing, operating and working on the stove. Keep the manual in a safe place, and ensure that it is available at all times.
  • Page 5: Requirements For Operating Your Wood-Burning Stove

    english 2. Requirements for Operating Your Wood-Burning Stove 2.1. External combustion air supply Every combustion process requires oxygen. This oxygen is extracted from the environment of the heating appli- ance. The exterior shell of modern buildings is very dense. As a result, insufficient fresh combustion air flows in, mak- ing an external supply of combustion air essential.
  • Page 6: Fuel

    english 2.3. Fuel Pellets We recommend using ENplus-A1 approved pellets. NOTE!: Using inferior quality pellets or other material will impair the functioning of your pellet stove and invalidate the warranty. When storing the pellets, it is essential that they are kept in a cool, dry place and free from contamination. Damp pellets impair combustion and clog the screw conveyor.
  • Page 7: Initial Operation, Using The Stove

    3. Plug in the power cable and set the toggle switch on the back of the stove to "I ". 4. The display will now show the Austroflamm logo. This is followed by the main operating menu with tem- perature indicators and hopper level.
  • Page 8 An air distribution module is available as an option for the RUBY model. This allows an additional room to be heated using warm air. The warm air is extracted in front of the rear wall of the firebox. For installation and any other information, please contact your Austroflamm dealer.
  • Page 9 english Function- Fill level indicator The fill level indicator informs you of the fill level of your pellet hopper. If the fill level falls below a certain value, a warning is shown on the dis- play. The fill level indicator must be updated manually each time the pel- let hopper is filled.
  • Page 10 english Setting a new heating time or editing the heating time Set the weekdays, heating time start, heating time end and room temperature as required. Save the heating time by pressing the "Save" icon. You will then return to the heating time list. To delete an existing heating time, proceed as follows: Highlight the heating time and press the "Delete heating time"...
  • Page 11 english Display - Settings Back Scroll list By pressing the “SETTINGS“ button in the menu list the “Settings” menu can be accessed. It is now possible to scroll up or down the list. By pressing the desired menu item, the function is activated. Menu item: Time / Date Setting the time of day is necessary for the correct heating time, the statistics function and for logging errors.
  • Page 12 The "SMART SPOT" radio-controlled room thermostat is available for your pellet stove. This SMART SPOT works via Bluetooth technology. When used, it must be activated once by selecting this menu item. Linking the 'Austroflamm knob' with the stove Tap 'Link'. Then briefly press...
  • Page 13 english Menu item: External thermostat The stove can also be controlled by an external thermostat, if required. Connect the potential-free contact of the thermostat at input "I03" & "GND" on the main control unit. A 2-pin plug is available as an option. (Art.No.
  • Page 14 Here you can see how many maintenance-free hours of operation your stove still has until a service is necessary. The service must be carried out by an approved Austroflamm technician. Menu item: Service menu This menu is reserved for the Austroflamm service technician.
  • Page 15: User Control Of The Stove By Means Of The Austroflamm Control Knob

    Your stove can also be operated using the rotary control. Important information: If the control knob does not react, go to the settings for 'Bluetooth devices' and check whether the AUSTROFLAMM control knob is linked. If not, proceed in accordance with the instructions provided under 'Add Bluetooth devices'.
  • Page 16: Operating The Stove Using The Ir Remote Control

    To install or set up the data connection, please refer to the instruc- tions for your WLAN module, or follow the installation instructions of the Austroflamm PelletControl app. Download the required "Austroflamm PelletControl" app here and then start it: Apple iOS...
  • Page 17: Operating Modes Of The Stove

    english 4. Operating modes of the stove 4.1. Functional diagram of your combi stove...
  • Page 18: Pellet Mode

    english 4.2. Pellet mode Automatic Ignition The stove can be started with the Start/Stop button in the status display or heat output dis- play.Optionally, it can be started via IR remote control or via the app. Pellet ignition is fully automatic and occurs in several phases. These phases are shown on the display.
  • Page 19 english Firewood start I Upon elapse of the 'Hybrid start' the furnace switches to this operating phase. Here it is en- sured that all pellets combust in the combustion bowl and that the firewood continues to be inflamed. If the firebox door is opened and closed again when the stove is idle (and the question "Have you inserted firewood?"...
  • Page 20: Warnings And Error Messages

    english 5. Warnings and error messages Alarms are displayed in yellow on the control panel. The pellet stove can continue to be used when an alarm is indicated. Alarms are displayed in red. The pellet stove is inoperable when an error is displayed. Warning code, Description Solution...
  • Page 21: Safety Temperature Limiter

    english In the event of an alarm or error, a yellow or red message is displayed giving details. To close the alarm display, press Closing the display does not clear the alarm. To clear the alarm, a solution to the problem must be found. However, the stove can still be operated in spite of the fact that the alarm indicator is still displayed.
  • Page 22: Cleaning And Maintenance

    The stove and its components must be cleaned according to the above table. Arrange for your pellet stove to be inspected and serviced annually by an Austroflamm technician before the start of the heating season.
  • Page 23: Cleaning Of The Flue Gas Passes - Mo Duo

    Cleaning of the flue gas passes – Mo Duo 6.2. Kippgefahr...
  • Page 24: Cleaning Of The Flue Gas Passes - Clou Duo

    english Cleaning of the flue gas passes – Clou Duo 6.3.
  • Page 25: Adjusting The Closing Force Of The Firebox Door

    english 6.4. Adjusting the closing force of the firebox door 6.5. Adjust position of ash container door...
  • Page 26: Adjusting The Firebox Door

    english 6.6. Adjusting the firebox door...
  • Page 27: Replacement Of The Storage Battery

    Replacing the battery 8. Warranty Our warranty covers the body of your AUSTROFLAMM pellet stove for 6 years, and all other steel and cast iron components and electrical and electronic components for 2 years from the date of first sale.
  • Page 28: Electrical Connection Diagram

    9. Electrical connection diagram Note: Repairs to your pellet stove must only be carried out by approved Austroflamm technicians. 9.1. For models with a permanently rotating feeder motor MAIN ELECTRIC DIAGRAM Door contact switch PWM to DC Converter RPM / HAL-IC...
  • Page 29 english *ADDITIONAL COMBUSTION VENTILATOR ELECTRIC DIAGRAM *ADDITIONALFEEDER MOTOR ELECTRIC DIAGRAM *ADDITIONAL GRATE MOTOR ELECTRIC DIAGRAM...
  • Page 30 english *ADDITIONAL AIR FLAP MOTOR ELECTRIC DIAGRAM *ADDITIONAL COMMUNICATION SPLITTER ELECTRIC DIAGRAM...
  • Page 31: Technical Data

    Technical Data 10.1. Mo Duo Flue outlet Suppy air Air distribution module Nominal thermal output (NWL) 9,4 kW Partial-load thermal output 2,8 kW 114 – 255 m³ Space heating capacity Efficiency 90 % CO content at NWL <250 mg/Nm³...
  • Page 32: Clou Duo

    english 10.2. Clou Duo Flue outlet Suppy air Air distribution module Nominal thermal output (NWL) 7 kW Partial-load thermal output 2,3 kW 98 – 190 m³ Space heating capacity Efficiency 89 % CO content at NWL <250 mg/Nm³ Flue gas temperature at NWL 188 °C Flue gas temperature at TL (partial load) 90 °C...