Download Print this page
Dexcom Tandem t Instructions Manual

Dexcom Tandem t Instructions Manual

Slim insulin pump with control-iq technology

Advertisement

Quick Links

Instructions for Use: Complete this Tool during Clinic appointment with Control-IQ user
Page 1:
Quick introduction to Control-IQ
Page 2-4:
Assessment, education, and settings adjustments—Enter pt information into highlighted boxes
and information will be auto-filled into electronic health record note
Page 5:
Electronic health record template
Page 6:
After visit summary to give to Control-IQ user after visit
AUTO CORRECTIONS
BASAL MODULATION
REPORT PREPARATION
• Analyze past two (2) weeks of data.
• Set the report settings to target range
of 70-180 mg/dL.
• Print Dashboard, CGM Hourly, Therapy
Timeline, and Settings pages.
Wear the
CGM
consistently
CLINIC Control-IQ Tool
Tandem t:slim insulin pump with Control-IQ Technology
C
How it CALCULATES
• HYBRID CLOSED-LOOP(HCL)
• Uses CGM glucose data to adjust the basal insulin delivery by increasing,
decreasing or suspending programmed basal rates
• Algorithm targets glucose levels 112.5-160 mg/dL
• Automatic correction boluses up to once per hour, 60% of a calculated
correction dose
A
What you can ADJUST
• Can change basal rates, I:C ratios, correction factors
• CANNOT change active insulin time (5 hours) or correction bolus target
(110 mg/dL)
• "Exercise Activity" targets glucose 140-160 mg/dL (to reduce insulin
delivery)
• "Sleep Activity", narrows glucose target to 112.5-120 mg/dL and prevents
automated correction doses overnight.
R
When to REVERT to open-loop
The system stays in HCL all the time except when CGM data is not
available. Users should consider turning off Control-IQ if they want to use
temporary basal rates.
E
How to EDUCATE
SLEEP ACTIVITY
See education points below.
S
SENSOR/SHARE characteristics
• Dexcom G6 sensor and transmitter: 10 day sensor life, factory calibrated, can
be used for diabetes management decisions without BG check.
• User can connect Dexcom transmitter to the Dexcom G6 app on a phone and
share data with others using Dexcom Follow app.
• Sensor glucose levels autopopulate into bolus calculator
THE 4 KEYS TO SUCCESS USING CONTROL-IQ
Set the
Sleep
Schedule
for every
night
BDCPantherDiabetes.org
Bolus
before
all meals,
and snacks
Give correction
bolus for
hyperglycemia,
if recommended
by bolus
calculator
PAGE | 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tandem t and is the answer not in the manual?

Questions and answers

Summary of Contents for Dexcom Tandem t

  • Page 1 CLINIC Control-IQ Tool Tandem t:slim insulin pump with Control-IQ Technology BDCPantherDiabetes.org Instructions for Use: Complete this Tool during Clinic appointment with Control-IQ user Page 1: Quick introduction to Control-IQ Page 2-4: Assessment, education, and settings adjustments—Enter pt information into highlighted boxes...
  • Page 2 Name of Control IQ user: STEP #1: Dashboard Report ASSESSMENT Dashboard | Thursday Feb 25, 2021 - Wednesday Mar 10, 2021 Highest Average Lowest Blood Glucose Blood Glucose Blood Glucose This is blood glucose data, may ignore if wearing CGM. Blood Glucose Summary A.
  • Page 3 STEP #2: CGM Hourly and Timeline Assessment Report Printed on Mar 11, 2021 Use CGM Hourly to CGM Hourly | Thursday Feb 25, 2021 - Wednesday Mar 10, 2021 understand mean CGM Hourly CGM Readings: Above Target Average Target Average Below Target Average Mid Range (25/75% - IQR) Highest-Lowest Reading...
  • Page 4 ettings Device Settings Active at the time of upload ettings STEP #3: Device Settings and Education Active at the time of upload Basal Rate Correction Factor Carb Ratio Target BG 0.720 u/hr 1u:50 mg/dL 1u:17.0 g 110 mg/dL Active at the time of upload Start Time Basal Rate Correction Factor...
  • Page 5 Tandem t:slim X2 with Control-IQ Hybrid Closed Loop (HCL) system to manage his/her diabetes (insulin pump + Dexcom G6 CGM + algorithm to maximize time in range). I reviewed the past 2 weeks of data. Overall, their CGM Time-In-Range (70-180 mg/dL) was %, Time Above Range (>180 mg/ dL) %, and Time Below Range (<70% mg/dL) was %.
  • Page 6 Have questions about your insulin pump? Have questions about your CGM? http://tandemdiabetes.com http://dexcom.com For Tandem customer support, call 1-858-375-1473 For Dexcom customer support, call 1-888-738-3646 For Tandem technical support, call 1-877-801-6901 For Dexcom technical support, call 1-844-607-9398 PAGE | 6...