7
Install the Case in the Window
Carefully slide the case into the window and
A
center the case. Lower the window behind the
top mounting rail. Mount the case to the
window sill using 6 type B screws.
6 Type B screws
Thread a type C bolt about 1/2 of the way
B
into the outer face of the shortest angle of
each V-support.
Type C bolt
Position the V-supports on the case bottom so
C
that they will be near the outside wall. Attach a
V-support to each side of the bottom of the case
using type A screws, 4 on each side.
Adjust the type C leveling bolts against the
D
outside wall so that the case has a slight tilt to
the outside. Use a level; about a 1/2 bubble
will be the correct case slant to the outside.
NOTE: Use a wood block between the leveling bolts
and the wall if the wall is weak or if the weight of the
air conditioner falls between the studs in the wall.
Extend the left and right accordion panels to
E
the vertical window sashes and attach the top
and bottom corners with 4 type B screws.
Top mounting rail
Type B
screw
Type B screw
Type B screw
Type B
screw
13