AEG EXN09C58HW Installation Manual page 16

Table of Contents

Advertisement

Available languages
  • EN

Available languages

16 www.electrolux.com
4. Connect and screw the wires onto the
terminal block as identified by their
colors.
5. Wrap wires that are not connected
with insulating tape so that they do not
touch any electrical or metal parts.
6. Secure the wires firmly with the cable
clamp.
7. Put the wiring cover back and screw it.
8. Reinstall the front panel.
Fig.3.5.2-2
NOTE:
• The wiring diagram as shown just for
reference only, please refer to the
label stickerd on the unit for correct
connection.
• All wires between indoor and outdoor
units must be connected by a qualified
electric contractor.
• If the length of the power cord is not
enough, please contact your supplier
for new power cord. Lengthen the
power cord by yourself is not allowed.
• After tightening the screws, pull the
wire slightly to confirm whether it's firm
or not.
• Do not connect two power cables
together to supply power to the air
conditioner.
• Do not extend the power cable
conductor by cutting.
Magnetic ring
(If supplied and
packed with the
accessories)
3.5.3 Installation of Outdoor
Electric Wires
1. Remove the handle on the right side
plate of outdoor unit.
Fig.3.5.3-1
Handle
2. Take off wire cable clamp. Pass the
wires through the hole of the Magnetic
ring(If supplied).
3. Connect and screw the power
connection cable and signal control
wire (for heap pump model only)
onto the terminal block following
corresponding identification numbers
and colors on the terminal blocks of
indoor and outdoor units.
4. To prevent water from entering, make
a trap ("U") in the connection wires as
shown in Fig.3.6.2-2.
5. Wrap wires that are not connected
with insulating tape so that they do not
touch any electrical or metal parts.
6. Fix the power connection wires with
wire clamps.
7. Reinstall the handle.
Terminal
block

Advertisement

Table of Contents
loading

Table of Contents