INDEX GENERAL CHARACTERISTICS ................. 3 DESCRIPTION OF THE FUNCTIONS ..............6 THE PROGRAMMING MENU ................10 PROBES AND MEASUREMENTS ..............11 PP471 ............11 MODULE FOR PRESSURE MEASUREMENT ................12 TEMPERATURE PROBES ................12 EMPERATURE MEASUREMENT TP47 ..............12 ONNECTING THE CONNECTOR Pt100 ............
GENERAL CHARACTERISTICS The HD2304.0 Manometer - Thermometer is a portable instrument that allows measurement of absolute, relative and differential pressure, and temperature. • The PP471 electronic module is used to measure the pressure. The module works as an interface between the instrument and the TP704 and TP705 series Delta Ohm probes.
Page 5
HD2304.0 1. Input for probes, 8-pole DIN45326 connector. 2. Battery symbol: displays the battery charge level. 3. Function indicators. 4. Secondary display line. 5. DATA/ENTER key: during normal operation displays the maximum (MAX), the minimum (MIN) and the average (AVG) of current measurements; in the menu, confirms the current selection.
DESCRIPTION OF THE FUNCTIONS The keyboard of the HD2304.0 Manometer – Thermometer is composed of double- function keys. The function on the key is the "main function", while the one above the key is the "secondary function". When the instrument is in standard measurement mode, the main function is active. Once the Settings Menu has been opened, by pressing simultaneously the DATA+UNIT keys, the secondary function is enabled.
Page 7
Disabling of the automatic turning off The instrument has an AutoPowerOff function that automatically turns the instrument off after about 8 minutes if no key is pressed during the intervening time. Press simultaneously the ON/OFF key and the HOLD key to disable this function. In this case, remember to turn the instrument off using the ON/OFF key: disabling of the automatic turning off is shown by the blinking battery symbol.
Page 8
Pressed together with the ON/OFF key, during turn on, the AutoPowerOff function is disabled (see the description of the ON/OFF key). UNIT/MENU key The UNIT key is used for the following functions: UNIT: by pressing this key the unit of measurement of the input probe is •...
Page 9
REL/ The REL key is used for the following functions: REL: it displays the difference between the current value and that measured on • pressing the key. The "REL" message is displayed on the left. To return to the normal measurement, press the key again.
THE PROGRAMMING MENU To access to the menu press simultaneously the following keys: Menu: Probe type: the "PRBE_TYPE" message is displayed in the comment line. The main line in the center of the display shows the type of probe connected to the instrument. The following probes can be connected to the input: TP704 and TP705 pressure probes combined with the PP471 module: the type •...
PROBES AND MEASUREMENTS The instrument measures absolute, relative and differential pressure using the PP471 SICRAM module and the TP704 and TP705 series probes. It also measures the temperature with a Pt100 sensor with SICRAM module or with direct 4 wire Pt100 probes.
Pt100 TEMPERATURE PROBES The instrument accepts the input of platinum temperature probes with resistances of 100Ω (Pt100). The Pt100 sensors are connected to 4 wires; the excitation current was chosen in order to minimize the sensor self-heating effects. All probes with module are calibrated in the factory; no calibration is usually required by the user.
Page 13
4. unscrew the ring on the opposite side as illustrated in the figure: 5. open the two module shells: the printed circuit to which the probe must be connected is housed inside. On the left there are the 1…4 points on which the sensor wires must be welded.
Pt100 IRECT CONNECTION OF WIRE SENSOR 4 wire Pt100 sensors can be Direct soldering to the Sensor soldered directly to the pins of connector flying female connector without making use of the TP47 board. The 4 wires of the Pt100 sensors have to be soldered as indicated in the figure on the left.
INSTRUMENT SIGNALS AND FAULTS The following table lists all of the indications displayed by the instrument in different operating and error situations. Display indications Explanation This appears if the SICRAM module connected to the channel PROB already been detected instrument, COMM LOST disconnected.
WARNINGS 1. Do not expose the probes to gases or liquids that could corrode the material of the sensor or the probe itself. Clean the probe carefully after each measurement. Some pressure probe models are suitable for measurement of non-corrosive gases or air and dry and not liquid only: check the membrane compatibility with the plant fluid.
INSTRUMENT STORAGE Instrument storage conditions: Temperature: -25…+65°C. • Humidity: less than 90%RH without condensation. • Do not store the instrument in places where: • • humidity is high; • the instrument may be exposed to direct sunlight; • the instrument may be exposed to a source of high temperature; •...
LOW BATTERY WARNING AND BATTERY REPLACEMENT The battery symbol on the display constantly shows the battery charge status. To the extent that batteries have discharged, the symbol "empties". When the charge decreases still further it starts blinking. In this case, batteries should be replaced. If you continue to use it, the instrument can no longer ensure correct measurement.
NOTES ABOUT WORKING AND OPERATIVE SAFETY Authorized use The technical specifications as given in chapter TECHNICAL CHARACTERISTICS must be observed. Only the operation and running of the measuring instrument according to the instructions given in this operating manual is authorized. Any other use is considered unauthorized.
TECHNICAL CHARACTERISTICS ECHNICAL CHARACTERISTICS OF THE ANOMETER HERMOMETER Instrument Dimensions (length x width x height) 140 x 88 x 38 mm Weight 160 g (complete with batteries) Material Display 2x4½ digits plus symbols Visible area: 52 x 42 mm Operating conditions Operating temperature -5…+50 °C Warehouse temperature...
ECHNICAL DATA OF PROBES AND MODULES IN LINE WITH THE INSTRUMENT PP471 RESSURE MEASUREMENT BY MODULE All TP704 and TP705 series Delta OHM probes can be connected to the PP471 module. See the table below for the technical specifications of the individual probes. PP471 SICRAM module for the measurement of absolute, relative and differential pressures.
Pt100 ONDE DI TEMPERATURA SENSORE CON MODULO SICRAM Model Type Range of use Accuracy -196 °C…+500 °C TP472I Immersion -50 °C…+300 °C TP472I.O Immersion TP473P.I -50 °C…+400 °C Penetration TP473P.O -50 °C…+300 °C Penetration -50 °C…+300 °C TP474C.O Contact TP475A.O -50 °C…+250 °C -50 °C…+400 °C TP472I.5...
ORDERING CODES HD2304.0 The kit is composed of the instrument HD2304.0, 3 1.5V alkaline batteries, operating manual, and case. The probes must be ordered separately. ROBES COMPLETE WITH SICRAM MODULE PRESSURE MEASUREMENT PROBES PP471 SICRAM interface module between instrument and TP704 and TP705 series Delta OHM probes.
Page 24
EMPERATURE PROBES WITHOUT SICRAM MODULE TP47.100.O Immersion probe, sensor Pt100 direct 4 wires. Probe's stem Ø3 mm, length 230 mm. 4-wire connection cable with connector, length 2 metres. TP87.100.O Immersion probe, sensor Pt100 direct 4 wires. Probe's stem Ø3 mm, length 70 mm. 4-wire connection cable with connector, length 2 metres.
Page 28
GHM GROUP – Delta OHM | Delta Ohm S.r.l. a socio unico Via Marconi 5 | 35030 Caselle di Selvazzano | Padova | ITALY Phone +39 049 8977150 | Fax +39 049 635596 www.deltaohm.com | sales@deltaohm.com WARRANTY Delta OHM is required to respond to the "factory warranty" only in those cases provided by Legislative Decree 6 September 2005 - n.