Overdischarge protection
The battery 13 is protected by the safety system
against deep discharge� In case of complete dis-
charge, the power tool is automatically switched off�
Attention: do not try to switch on the power tool
when the protection system is activated the bat-
tery 13 can be damaged.
Indicators of the state of battery charge (see
fig. 8.7, 10.7)
With the push of the button 10 the indicators 11 show
the state of charge of the battery 13 (see fig. 8.7, 10.7).
Carrying belt (see fig. 4)
For easy transportation, as well as for greater mobil-
ity while working, use the carrying belt 18� Attach the
belt 18 to the fasteners 1 (see fig. 4). If necessary,
adjust the length of the belt 18 so that it is comfort-
able for you to carry the power tool�
Adjustment of the spray swath shape (see
fig. 12, 13)
The spray swath shape can be adjusted by turning the
spray atomizer head 32 (see fig. 12, 13).
Recommendations on the power tool op-
eration
Caution: The solution for spraying must
have the consistency of water, do not
spray more dense substances, this may
damage the power tool.
• Prepare the solution for spraying and fill the tank 8�
• Adjust the length of the curved tube 24�
• Turn on the power tool and start spraying� Adjust the
spray swath shape, if necessary�
• If the solution is sprayed unevenly while in opera-
tion, check the volume of liquid in the tank 8� Add it,
if necessary� It is also possible that the hole of the
nozzle 32 or the holes in the spray atomizer head 33
are clogged, if necessary, clean them as described
below�
• After finishing work, turn off the power tool and dis-
connect the sprayer top 2� Drain the remaining solution
from the tank 8, and rinse the cap 6, tank 8, hose 16,
spray atomizer 17 thoroughly, as described below�
Power tool maintenance / preventive
measures
Before carrying out any works on the power tool
remove the battery 13.
Battery maintenance instruction
• Charge timely before the battery 13 is completely
exhausted� Stop operation in low power and charge it
immediately�
• Do not overcharge when the battery 13 is full, other-
wise it will shorten the life time�
• Charge battery 13 in the room temperature of 10°C
to 40°C (50°F to 104°F)�
• Charge battery 13 every 6 months without operation
for a long time�
• Replace worn out batteries in time� Decline of pro-
duction or a significantly shorter runtime of the power
tool after charging indicates aging of the battery 13 and
the need for replacement� It should be taken into ac-
count that the battery 13 may discharge faster if the
works take place in the temperature below 0°С.
• In case of long time storage without use, it is recom-
mended to store the battery 13 at room temperature, it
should be charged to 50%�
Cleaning of the power tool (see fig. 5-6, 14)
Caution: it is strictly forbidden to leave
and store the solution for spraying in
the tank, and also not to rinse the power
tool parts after each use, this may cause
damage to the power tool, in which case you will
void the right to warranty repairs.
• After finishing work, turn off the power tool.
• Disconnect the sprayer top 2 (see fig. 5).
• Unscrew the cap 6 (see fig. 6) and rinse it and the
tank 8 thoroughly with running water�
• Fill the tank 8 with water (2 liters approximately),
close the cap 6, install the sprayer top 2, and turn on
the power tool�
• Spray clean water to rinse the power tool pump, the
hose 16, and the spray atomizer 17� Remember, the
sprayed water contains the chemical that you sprayed
before, take precautions�
• If necessary, you can unscrew the nozzle 32 and
clean the hole in it, as well as the holes in the spray
atomizer head 33 with a wire of suitable diameter (see
fig. 14). Caution: do not use steel wire, needles,
drills, etc. for this procedure - you can damage the
nozzle 32 or the spray atomizer head 33�
• Rinse all used accessories with running water - con-
tainers for mixing the solution, the funnel 27, etc�
• An indispensable condition for a safe long-term ex-
ploitation of the power tool is to keep it clean� Regularly
flush the power tool with compressed air thought the
ventilation slots 3�
After-sales service and application service
Our after-sales service responds to your questions
concerning maintenance and repair of your product as
well as spare parts� Information about service centers,
parts diagrams and information about spare parts can
also be found under: www.crown-tools.com�
Transportation of the power tools
• Categorically not to drop any mechanical impact on
the packaging during transport�
• When unloading / loading is not allowed to use any
kind of technology that works on the principle of clamp-
ing packaging�
Li-Ion batteries
The contained Li-Ion batteries are subject to the Dan-
gerous Goods Legislation requirements� The user can