The EconoMi$er X system utilizes gear-drive technology with a
direct-mount spring return actuator that will close upon loss of
power. The EconoMi$er X system comes standard with an
outdoor air temperature sensor, mixed air temperature sensor (also
called supply air temperature sensor). Outdoor enthalpy, indoor
(return) dry bulb or enthalpy, and CO
field installation.
Standard barometric relief dampers provide natural building
pressurization control. An optional power exhaust system is
available for applications requiring even greater exhaust
capabilities. The power exhaust set point is adjustable at the
EconoMi$er X controller.
See Tables 1-3 for package usage. See Table 4 for package
contents. See Table 5 for sensor usage.
IMPORTANT: Read these instructions completely before
attempting to install the accessory economizer.

Compliance

Economizers meet California Energy Commission Title 24-2016
prescriptive section 140.4 (damper leakage etc.), and mandatory
section 120.2.i for Fault Detection and Diagnostic controls.
Economizers meet ASHRAE 90.1-2016 damper leakage
requirements as stated in Section 6.5.1.1.4 and Table 6.4.3.4.3,
and meet 2016 Fault Detection and Diagnosis requirements in
section 6.4.3.12.
Economizers meet IECC 2012 section C402.4.5.2 and, IECC
2015 sections C403.2.4.3 and C403.3.3.5 for outside air, return
air, and relief air damper leakage requirements, and IECC 2015
section C403.2.4.7 for Fault Detection and Diagnostic
requirements.
NOTE: IECC 2015 section C403.2.4.7.1 requires differential
return air sensor, which must be ordered separately.
Relief air, outside air, and return air (volume) dampers are AMCA
rated.
Table 1 — Carrier Usage Chart
CARRIER MODEL NUMBER
48/50TC 17-24
48/50HC 17-20
48/50LC 14
48/50TCQ 17-24
48/50TC 28-30
48/50HC 24-28
48/50LC 16-26
Table 2 — Bryant Usage Chart
BRYANT MODEL NUMBER
580J, 558J 17-24
581J, 551J 17-20
548J 17-24
580J, 558J 28
581J, 551J 24-28
Table 3 — ICP Usage Chart
ICP MODEL NUMBER
RGS, RAS 181, 183, 210, 213, 240, 243
RGH, RAH 181, 210
RHS 181, 240
RGS, RAS 300, 303, 336
RGH, RAH 240, 300
sensors are available for
2
ECONOMI$ER
X PART
®
NUMBER
CRECOMZR074A00
CRECOMZR075A00
ECONOMI$ER X
PART
®
NUMBER
CRECOMZR074A00
CRECOMZR074A00
ECONOMI$ER X
PART
®
NUMBER
CRECOMZR074A00
CRECOMZR075A00
Table 4 — Package Contents
ECONOMIZER PART
NUMBER
CRECOMZR074A01
CRECOMZR075A01
2
QTY
CONTENTS
1
Damper Assembly with Shroud
1
Upper End Economizer Panel
Bottom Panel with Relief Damper
1
(for vertical only)
Bottom Panel #2 with Return Duct
1
Opening
(for horizontal only)
Side Replacement Panel
1
(for horizontal only)
3
Filter Supports
3
Central Retainer
1
Hood Top
1
Left Hood Side
1
Right Hood Side
2
Side Retainer
2
Top Diverters
3
Deflector
4
Outside Air Filter Screens
Mixed (Supply) Air Temperature
1
Sensor HH79AH001 and Harness
1
50HEHMRAE-A10 Harness
Parts Bag with W7220 Controller
1
with 50HEHMRAE-A00 Harness
Attached
60
Screws #10 - 16 in. x 7/8 in.
14 ft
Seal Strip 1/8 in. x 3/4 in.
1
Damper Assembly with Shroud
1
Upper End Economizer Panel
Bottom Panel with Relief Damper
1
(for vertical only)
Bottom Panel #2 with Return Duct
1
Opening
(for horizontal only)
Side Replacement Panel
1
(for horizontal only)
3
Filter Supports
3
Central Retainer
1
Hood Top
1
Left Hood Top
1
Right Hood Top
2
Side Retainer
2
Top Diverters
3
Deflector
4
Outside Air Filter Screens
Mixed (Supply) Air Temperature
1
Sensor HH79AH001 and Harness
1
50HEHMRAE--A10 Harness
Parts Bag with W7220 Controller
1
with 50HEHMRAEH-A00 Harness
Attached
60
Screws #10 - 16 in. x 7/8 in.
14 ft
Seal Strip 1/8 in. x 3/4 in.