Calibration; How To Calibrate (Cis Setting) - SeeTech ST-150 Service Manual

Hide thumbs Also See for ST-150:
Table of Contents

Advertisement

SERVICE MANUAL FOR ST-150(F)

5. CALIBRATION

5.1 How to calibrate (CIS Setting)

→ Before API Version R120613
1. Long press "START/STOP" key
2. Select "4. MACHINE SETTING"
3. Enter the password "1111" + "SET" Key
4. Select "1. CIS Setting"
5. Select "CNT" by pressing "CURR" key
6. Put a CIS calibration paper (just one piece) on the hopper
7. Press "Send" key
8. In red circle, the front value (95) is for IR, the next value (235) is for Gray
9. The
IR value
should be
94~96
and the
Gray value
should be
234~236
10. If the IR value is higher than 96, decrease IR Level by pressing "SET", "CLEAR", "NUMERIC" Key