Siemens SCALANCE XB-000 Operating Instructions Manual page 71

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-000:
Table of Contents

Advertisement

Technical specifications
Overvoltage protection at input
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Design, dimensions and weight
Immunity
Emission
Degree of protection
MTBF (EN/IEC 61709; 40 °C)
Housing material
Weight
Dimensions (W x H x D)
Installation options
Switching properties
Aging time
Max. number of learnable MAC ad‐
dresses
Response to LLDP frames
Response to spanning tree BPDU
frames
CoS acc. to IEEE 802.1Q
QoS priority queues
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Maximum frame size
Forwarding of PRP frames (Parallel Re‐
dundancy Protocol)
SCALANCE XB-000
Operating Instructions, 01/2022, A2B00077300-11
During operation
During storage
During transportation
During operation
During operation
EN 61000-6-2
EN 61000-6-4
IP20
214 years
Polycarbonate (plastic)
180 g
45 x 100 x 87 mm
Mounting on a DIN rail
Wall mounting
45 seconds
1024
Blocking
Forwarding
Yes
4
Yes
1536 bytes
Yes
Technical specifications
8.6 SCALANCE XB008
PTC resettable fuse (0.6 A / 60 V)
-10 ℃ to +60 ℃
-40 ℃ to +80 ℃
-40 ℃ to +80 ℃
≤ 95 % no condensation
≤ 2,000 m above sea level at max. +60 °C
ambient temperature
< 3,000 m above sea level at max. +55 °C
ambient temperature
< 4,000 m above sea level at max. +50 °C
ambient temperature
71

Advertisement

Table of Contents
loading

Table of Contents