ELECTRICAL SERVICE
e
Note
-
Always refer to
the inside
of
the
electrical box
cover
for
the
correct
wiring diagram,
and
always
refer
to
the
nameplate
on the exterior
of
the
cabinet
for
the
correct
electrical specifications.
EWARNING
-
ELECTRICAL SHOCK CAN
CAUSE
PERSONAL
INJURY OR DEATH.
Disconnecr all
power
supplies
before installing
or
servicing
electrical
devices.
Only
trained and
qualified service
personnel
should
install,
repair or service this equipment.
9wanr,[n[c-
THE
uNrr
MUST
BE
pRopERLy
GROUNDED!
The main
electrical
service must
be
protected
by
a
fuse
or
circuit
breaker and
be
capable
of providing
the
amperes
required
by
the
unit
at
nameplate voltage.
A11
wiring
must
comply
with
the national electrical
code and/or any
local
codes
that may apply.
Access
to
the
line
voltage contactor
is
through the knockouts
provided
on the side
of
the
heat
pump
next
to
the
front
corner. Route
EMT or flexible
conduit
with
appropriate
size and
tlpe
of
wire.
Ensure adequate
supply
wiring
to minimize
the
level
of
dimming lights during
compressor startup on
single-phase
installations.
Some
dimming is
normal, and a variety
of
start-assist accessories
are
available
if
dimming
is
objectionable.
elmportant
-
some models already have
a
factory-installed
start
assist.
Do
not
add
additional
start
assists
to
those
units.
9ClUffOn -
route
field
electrical
wiring
to
avoid
contact
with
electrically
live
bare metal parts inside
the
elecfrical
box
and
to
avoid contact
with
the surface
of
the
factory-installed
start
assist
(if
provided).
VCAUTION
-
Three-phase
units must
be
wired
properly
to
ensure
proper
compressor
rotation. Improper rotation
may result
in
compressor damage.
An
electronic
phase
sequence
indicator must be
used
to
check supply-wiring
phases.
Also, the
"Wild-
1eg
of
the
three-phase
power
must
be connected
to
the
middle
leg
on the
contactor.
Important
-
Only
the
ECONAR
PumpPAKrM is
certified
to be wired
directly
to the
compressor contactor and
can
be
grounded
in
the
grounding
lug
for
208/230Yac. An
alternative
loop
pump
or
a pump
for
a different
supply
voltage must
be
powered
from
a
separate
fused power
supply
and
controlled through
an
isolation relay that
has
its
coil
wired to
the
contacror
circuit.
An
intemal pump
relay provides the electrical
power
10
through the 3-pole terminal
block
(BP)
for
rhe
hydronic-
side circulator
pump.
The use
of
impedance
protected
pumps
eliminates the
need
for
additional fusing.
Do
not
comect
more than
a
1/3 horsepower
pump to
the
internal
pump
relay
terminal
block.
eNote
-
The GW240
does
not have
aa
internal
pump
relay.
A
pump
for
the GW240,
or
a
pump larger than
1/3 horsepower
on any other unit,
must
be
powered
from
a
separate
fused
power
supply
and
controlled through an isolation
relay
that
has
its
24Vac
coil
wired to
the
Y
and
X
terminals.
VIIII.
aAYOLT CONTROL CIRCUIT
Note
-
Always refer
to the
inside
of
the electrical box
cover
for
the
correct
wiring
diagram.
There
are three basic sections
of
the
low
voltage circuit;
transformer, remote
hydronic
confrols,
and
controller.
A. Transformer
An
internal
transformer provides
24Yac
for all
control
features
of
the
heat
pump. Even though the transformer is
larger than the
industry
standard,
it
is
in
a
warm
electrical
box
and can
be
overloaded
quickly. Table
5
shows
the
transformer
usage
for
the
hydronic
heat pumps.
Table
5
-
Transformer
@Important
-
If
the system's extemal conffols
require
more than shown
in
Table 5,
an external transformer
and
isolation relays should
be
used.
Table
5
shows
that
the
heat
pump's internal
transformer can
easily
power
the
24-
Volt
system.
In
contrast, Figure
4
shows
a
fan
coil
system
with its own
power supply,
which
must interface
to
the
heat
pump
to put
the
heat
pump
into
the
cooling
mode.
This can be
accomplished
by
using
the fan
coil's
independent
power supply
to
energize
the
coil
of
an
isolation
relay with
contacts located
in
heat
pump's
control circuit.
9WARNING
-
The GW240
uses a
large-capacity
24yac
Control
Transformer,
and
field
wiring to
remote
hydronic
conffols
must
be suitable
for NEC
Class
1.
elmportant
-
Miswiring
of
24Yac
control
voltage
on
system
controls
can
result
in
transformer burnout.
elmportant
-
Units with
a
dual voltage
ratfurg
(example,
208/230)
are
factory-wired
for
the
higher
volrage
7
t6
(2)
4
N/A
18
lz
2
I
Nre
4 (2)
Ll2
2
10
10
33VA
50
72YA
150
)
Component
37-87
240
Contactor
Pump
Relav
Reversins
Valve
8
Controller
20-1038
Contactor
Pilot
Relavs
Plug Accessory (PA)
Total
Transformer
VA
size