Service And Lockout Lights; Room Thermostat Operation; Desuperheater (Optional) - Econar GeoSource Ultra GW Series Installation And Operating Instructions Manual

Hydronic
Table of Contents

Advertisement

ensure
proper
flow
for
the
system.
Set
the
system
to the
"OFF'
position.
The compressor
will
shut
down
in
1
to 2
seconds.
Next, turn the
setpoint
to its
lowest
setting. Place
the
system
to run
in
cooling. The
compressor
will
start
afler
an anti-short-cycle period
of
70
to
130
seconds
from its
last
shutdown.
The anti-short-cycle period
is
indicated by
the
red
light
on
the
conftoller.
After
5
minutes
of
cooling
operation, check
hydronic
side
return and
supply water
temperatures.
A
water
temperatue drop
of
101F
to
15"F
is normal (variation
in
water
temperature and water
flow
can
cause
slight
variations). Use
a
single pressure gauge
to
check the
fluid
pressure
drop through the heat
exchangers to
ensure
proper
flow
for
the system.
Set the system and
the setpoint
for
normal operation.
Instruct the owner on correct operation
of
the
entire
heat
pump
system.
The
unit
is now operational.
X.
SERVICE
and
LOCKOUT
LIGHTS
With
proper
installation,
the
ECONAR
GeoSource
Ultra
hydronic
heat
pump
requires
only minor
maintenance,
such
as periodic cleaning
of
the
ground
water
heat
exchanger
for
heat pumps
hstalled
in
ground-water
applications.
Setting
up
regular
service checkups
with
your ECONAR
dealer
could be
considered.
Any
major
problems
with the
heat
pump
system
operation
will
be
indicated on
the
lockout
lights.
VCAUTION
-
During
evacuation
of
refrigerant
of
a
system
not having
wrtifreeze
protection
of
either
the
ground-side or
the
hydronic-side,
water
in
the unprotected
heat
exchanger must
be
removed
or contiauously
flowing
to
avoid
a
potential heat
exchanger
failure
caused
by
freeze
rupture.
The
heat
pump controller
(and
a
room
thermostat,
if
part
of
the
system
installation)
will
display a
system lockout.
If
lockout
occurs,
follow
the
procedure below:
1)
Determine and record
which
indicator
lights on
the
Controller
are
illuminated.
(Refer
to
Section
XIV
for
more information
on
possible
causes
of
Lockout
Conditions.)
2)
Check
for
correct water supply
from
the ground
loop
or ground water
system.
3)
Check
for
correct water supply
on the
hydronic
side.
4)
Reset
the
system
by
disconnecting
power
at
the
circuit
breaker
for
one
minute
and then
reapplying.
5)
If
shutdown reoccurs,
I
call your ECONAR
dealer.
Do
not
continuously
reset
the
lockout condition
or
serious damage
may occur.
eNote
-
Improper
{luid flows
or
incorrect antifreeze
levels
are
the
cause
of almost
all
lockouts.
XI.
ROOM THERMOSTAT
OPERATION
Installations may include
a
wide
variation
of
available
electronic room thermostats,
and
most
of
them
requi-re
to
be
configured
by
the
Installer
(according to
the
Installation
Guide included
with
the
thermostat)
and
checked
out after being installed.
elmportant
-
At
a
minimum:
1.
Ensure the
thermostat is
set
up
for
the
"System
Type"
it
is installed
on.
2.
Ensure the
thermostat is configured
for "Manual
Heat/Cool Changeover."
3.
Change
other
Installer
Settings
only
if
necessary.
4.
Remember
to press
"Done"
to
save the
settings
and
to
exit "Installer
Setup."
5.
Run
the system
through
all
modes
of
operation
in
the
thermostat instructions to
ensure
correct operation.
XIT.
DESUPERHEATER
(OPTIONAL)
A
GeoSource
Ultra
unit
equipped
with a
double-wall
vented
desuperheater can
provide
supplemental heating
of
a
home's domestic
hot
water
by
stripping
some energy
from the
superheated
gas
leaving
the
compressor
and
fansferring
it
to
a
hot
water tank.
A
desuperheater
pump,
manufacfured
into the unit,
circulates
water
from
the
domestic
hot
water tank,
heats
it
using a double
walled
water-to-refrigerant
heat exchanger, and
returns
it
to
the
tank.
€Note -
A
desuperheater
is not available
on the
GW240.
The
desuperheater
only provides
supplemental
heating
when the
compressor
is
already
running
to
heat
or
cool
the
conditioned
space. Because
the
desuperheater
is using
some energy
from
the heat
pump
to
heat
water, the
heat
pump's capacity
in
the
winter
is
about
107o
less
than
a
unit
without
a
desuperheater.
During extremely
cold
weather,
or
if
the heat pump cannot keep
up
with
heating
the
space,
the
desuperheater
fuse
may be removed
to
get
full
heating
capacity
out
of
the
unit.
9W,q.nNnqC
-
Oo not
remove the desuperheater's
high
temperature
cutout switch,
or
tank
temperatures could
become dangerously
high. The
desuperheater's
high
temperature
cutout switch
is
located
on the return
line
from the water
heater and
is
wired
in
series
with
the
desuperheater
pump
to
disable
it
from
circulating
at
entering
water
temperature
above 140"F.
If
the
tank
temperatures
become uncomfortably
hot,
move
this
switch
to
the
leaving
water
line, which
will
reduce
the
tank maximum temporatures
10"F
to
15oF.
13