Econar GeoSource Invision 3 Q Series Installation And Operating Instructions Manual page 4

Dual circuit, vertical forced air
Table of Contents

Advertisement

I.
INTRODUCTION TO
ECONAR HEAT
PUMPS
ECONAR
Energy
Systems,
Corp.
has
been
producing
geothermal
heat
pumps in Minnesota
for
over
flfteen
years.
The cold
winter
climate
has
driven
the design
of
ECONAR
Energy
System's
heating
and
cooling
equipment
to
what
is
known
as
a
"Cold Climate"
geothermal
heat
pump.
This
cold
climate technology
focuses
on
maximizing
the
energy savings available
in
heating dominated regions
without sacrificing
comfort.
Extremely efficient
cooling,
dehumidification
and
optional domestic hot water heating
are also
provided
in
one
neatly
packaged system.
Geothermal
heat
pumps
get
their
name
from
the
ffansfer
of
heat
to
and
from
the
earth.
The
earth
coupled
heat
exchanger (geothermal
loop)
supplies
the
source
energy
for
heating
and absorbs the
discharged energy
from
cooling.
The
system
uses
a
compression cycle, much
like
your refrigerator, to
collect
the earth's
energy supplied
by
the sun and
uses
it
to heat
your
home.
Since ttte process
only
moves heat and does
not
create
it,
the
efficiencies
are
three
to
four
times higher than
the
most
efficient fossil
fuel
systems"
This
guide
discusses the
GeoSource
Invision3
series heat
pumps that
are
equipped
with
a
dual compressor
configuration to
supply
multiple
stages
of
heating,
cooling
and
hot water
combinations"
GeoSource
Invision3
heat
pumps
are
specifically
designed
for
domestic hot water
heating applications where
a
double walled, water cooled
condenser
coil
is
used
to
safely
heat
all of
a
family's
hot
water
needs.
Safety
and
comfort
are
both inherent to,
and designed
into
ECONAR
Energy
System's
geothermal
heat pumps.
Since the system
runs completely
on
electrical
energy,
your
entire home
can have
the
safety
of
being
gas
free.
"
The
best
engineering
and
quality control
is
built
into
every
ECONAR
heat
pump
built.
Proper application
and
correct
installation
will
assure
excellent performance
and
customer satisfaction.
ECONAR's
commitment to
quality is written
on
the side
of
every
heat
pump
we
build.
Throughout
the
building
process the
technicians that
build
each
unit
sign
their
names
to
the
quality
assurance
label after completing
their
inspections. As
a
fina1
quality
test,
every
unit
goes
through
a
fulI
run
test
where
the
performance and
operation
is
verified in
the
heating,
cooling,
and
hot
water
modes. No
other manufacturer
goes
as
far
as
to run
a
full
performance check to
assure system
quality.
,6S
IMPORTANT**
Service
of
refrigerant
based
equipment
can be hazardous
due
to
system
pressure
and
23O
volt
electrical
energy.
Only
trained
or qualified
service
personnel can
install,
repair or
service
refrigerant equipment.
2
I
Warning:
Turn
off
the
main switches before
performing
service or maintenance to this
unit.
Electrical
shock can
cause
personal
injury.
The
installer
is
responsible
to
see
that
all local
electrical,
plumbing,
heating
and
air
conditioning
codes
are
followed.
II.
GeoSource
INVISION3
FEATURES
The GeoSource
Invision3
is
ECONAR's
most
advanced
geothermal
heat
pump.
The
design
of this
system
took
into
account
issues such
as
environmental impact,
power
supply
efficiency,
cold climate
home
construction,
and
global energy
trends. This unit
offers unique
and
innovative features to
optimize
the
efficiency, comfort
and
reliability
of
a
home
space
conditioning
system.
The GeoSource
Invision3
is available
in four
configurations:
2heat,l
cool,
I
DHW
standard
capacity
2od
stage
-DHW
2heat,
I
cool,
1
DHW
extra capacity
2oo
stage
-DWR
2heat,2
cool,
standard
2od
stage
capacity
-000
2heat,2coo1,
standard
2"d
stage
capacity
with
desuperheater
-SUP
The
frst
two
models take
advantage
of typical
heating
and
cooling
cold climate load
profiles.
In cold
climate
applications, more
he-ating
is
required
than
cooling'
The
GeoSource
Invisionr
provides
two
heating
stages
to meet
the
higher heating load
and one
cooling
stage.
In
heating
mode,
the
second stage
is
shared
befween
the
building's
heating
and the
hot water heating needs. The
second
stage
in
cooing
then becomes
available
for
domestic
hot
water
heating.
The hot water
can be used
exclusively for DHW
needs
or,
ifplumbed
properly
per local
code, can be used to
provide
radiant
floor
heating.
The
-DWR unit
provides
additional
heat
to
the
2'd
stage
ofheating.
This
additional
heat
is
beneficial
to
both forced air
and
hot water
loads,
especially when radiant
floor
heating is part
of
the system"
The last
two
are
forced air heating
and
cooling only
where
one has
a
desuperheater and
are
best
applied
ia
applications
requiring
high
cooling
or
dehumidification
capacities.
The
desuperheater
provides supplemental
hot
water
in
heating
and
cooling,
tp
to
65Vo
of
a
homes
domestic hot water
needs, and takes advantage
offree
heat
available whenever
cooling
is
in
operation.
A.
Domestic Hot
Water (DHW)
Heating
GeoSource
Invision'heat
pumps
have
the
ability
to
heat
i
1007o
of
a
typical
home's domestic hot water
needs.
GeoSource
Invisions
units
of
the
2-Heatl1-CooU1-DHW
variety
(-DHW
and
-DWR option)
are connected
directly
to
an
electric hot water
heater and
supply
from
15,000
to
50,000
Bfiltu
(4.4
ta
14.7
kwhr)
of
heat
depending on
I

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents