Econar GeoSource Invision 3 Q Series Installation And Operating Instructions Manual page 20

Dual circuit, vertical forced air
Table of Contents

Advertisement

Thermostat
Check
for
loose or broken
wires
at
compressor, capacitor, or contactor,
Wiring
Replace fuse or reset
circuit breaker.
(Check
for
correct
size
fuse
!t
ctrcu4
llgakgl)
Blown
Fuse
High or Low
Pressure
Controls
The
unit
could be
off
on the
high
or low-pressure
cutout
control.
Check water
GPM,
air
CFM
and
filter,
ambient temperature and loss
of refrigerant.
If
the
unit
still
fails to
run, check
for faulty
pressure
controls
individually.
Replace
if
defective.
Check capacitor,
if
defective remove, replace
and
rewire correctly.
Defective Capacitor
Voltage
Supply
t
ow
If
voltage is
below minimum
voltage specified on the
data
plate, contact
local
power
company.
Check
voltage
at
compressor
for
possible open
terminal.
Low
Voltage
Circuit
Check transformer and fuse
for bum
out or voltage
less
that
I
8
volts. With
a
voltmeter,
check signal
from
thermostat
at
Y
to X,
Ml
on
controller to X,
check
for
24
volts
across
the compressor contactor.
Replace component that
does
not energize.
Compressor Overload Open
ln
all
cases
an
"internal"
compressor overload is
used. If
the compressor
motor
is too hot, the
overload
will
not reset
until
the compressor cools down.
Internal winding
grounded to the compressor shell. Replace the
compressor.
If
compressor
burnout.
replace
inline
filter
drier.
Compressor
Motor
Grounded
Check
continuity of
the compressor
windings
with
an
ohmmeter.
lf
the
windings
are
open, replace the
compressof.
Compressor
Windings
Open
Try
an
auxiliary
capacitor
in parallel with
the run capacitor
momentarily.
ff
the compressor
still
does
not
start. replace
it.
Blower motor
runs
but
compressor
does
not, or
compressor
short cycles.
Seized Compressor
Improoerlv
located thermostat (e.g. near
kitchen, inaccurately
sensing the
comfort level in
living
areas).
Thermostat
Loose
wiring
connections,
or control
contactor defective.
Wiring
and
Controls
Unit
short
cycles
Compressor Overload Engaging
Compressor overload
works
on
high
temperature.
A
compressor
running
hot may
be due
to lack
of
refrigerant
charge or
faulty
high-pressure
lockout.
Water
Lack of sufficient
pressure,
temperatue or quantity of
water.
Recalculate heat gains or
losses
for
space
to
be
conditioned.
If
excessive,
rectify by
adding
insulation,
shading,
etc.
Unit
undersized
Air
leaks
in ductwork
Check
for
leaks
in ductwork
or
introduction of
ambient air
through doors/windows
Thermostat
Improperly
located thermostat (e.g. near
kitchen, not
sensing the
comfon level
in living
areas).
Check
anticipator
setting.
Aidlow
Refriserant
Charse
Low
on
refrigerant
charge causing
inefficient operation. Adiust only
after checking
CFM
and
GPM.
Reversing
Valve
Defective reversing
valve creating bypass
of refrigerant from
discharge
to suction
side
of
compressor.
When
it
is
necessary
to
replace
the
reversing valve, wrap
it
with
a
wet
cloth
and
direct
the heat away.
Excessive heat
can
damage the valve.
Insufficient
cooling or
heating.
Desuperheater
The desuperheater
circuit (in-line fuse)
should be disconnected
during cold
weather
to allow
full
heating
load
to
house.
Reversing valve
does
not shift
Defective
solenoid
valve
will
not
energize.
Replace solenoid
coil.
Unit
does
not
cool
(Heats
Onlv)
Reversing valve
does
not shift,
the valve
is
stuck
The solenoid valve
is
de-energized due
to miswiring
at
the
unit
ff
thermostat-correct
wiring.
Replace
if
valve
is
tight
or
frozen
and
will
not
move.
Switch from
heating
to cooling
a
few
times
to
loosen valve.
Diny
Air
Filter
Check
filter.
Clean or replace
iffound
dirty.
Aidlow
Lack of
adequate
airflow
or
improper distribution of
air.
Check the
motor
speed and
duct
sizing.
Check
the
filter,
it
should
be
inspected every month and changed
if dirty.
Check
for
closed
registers.
Remove
or
add
resistance
accordingly.
Blower
speed set
to
low
Low
air
temperature
Evaporator (air
coil)
ices over
in cooling
mode.
Move
jumper
to the
next
highest
speed
setting.
Room temperatures
below
65"F may ice over the evaporator.
Unit
not
level
Level vertical
units.
Water drips
from unit.
Condensate
drain line kinked or
plugged
Clean condensate
drain.
Make
sure
external condensate
&nin
i5
ilstallsd with
adequate
drop and
pitch.
Compressors
Make
sure
tle
compressors
are
not
in direct
contact
with
the
base
or
sides
of
the
cabinet.
Liquid
slugging
or
high-pressure operation
creates
noise.
Blower
and
blower motor
Blower
wheel
hitting
the casing, adjust
for
clearance and
alignment. Bent blower,
check
and
replace
if
damaged.
Loose
blower
wheel on shaft, check and tighten.
Contactors
Check
for
low
supply voltage,
low transformer
output, or
ffansformer
tap
setting.
lf
the contactor
noise
in
the contactor
could
be
to control
voltage
less
than
18
volts.
or
or
corroded
or coil
contacts
are
or
Rattles
and
Vibrations
Check
for
loose screws, panels, or
internal components.
Copper
could be
hitting
the metal
surfaces. Carefully
readiust
by
bending
slightly.
Water
and
Airborne
Noises
DHW/Desuperheater
Plumbing
Certain
piping configurations
can cause
a
resonadng
sound
in
remote locations
thoughout
the
Fastening the
piping
more sequrely,
vibration
absorbing
fiftings,
or
replumbing
may be necessary
Noisy
Operation
Cavitating
Pumps
Purge air
from
closed
loop
system.
and
Lack of
adequate
airflow
or
improper distribution of
air.
Check the
motor
speed
and
duct
the
filter,
it
should
be
inspected every month and changed
if dirty.
Remove
or
add
resistance
ductwork
will
cause
high
airflow
velocities
noisy
operation.
Excessive water
through
the water
coil
will
cause a
squealing
sound.
Check the
l8
but
the noise.
water
flow,
ensuring
adequate
flow for
good
PROBLSIW
PASSIBI,E
C,A.I]SE
Check settins.
calibratior
f