When Replacing Eeprom (Memory) Ic - Toshiba MD30H82 Service Manual

Color television/dvd video player
Hide thumbs Also See for MD30H82:
Table of Contents

Advertisement

CONFIRMATION OF CHECK SUM, POWER ON TOTAL HOURS, MICON VERSION AND
DIGITAL TV MICON FIRMWARE
Initial total of MEMORY IC, POWER ON total hours, MICON VERSION and Digital TV MICON Firmware can be checked on
the screen. Total hours are displayed in 16 system of notation.
NOTE:
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
1.
Turn on the POWER, and set to the TV mode.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (8) on the remote control for more than 2 seconds.
4.
After the confirmation of each check sum, POWER ON total hours, MICON VERSION and Digital TV MICON Firmware, turn off
the power.
Digital TV MICON Firmware
Initial setting data check sum.
Rom correction data check sum.
VOLUME CURVE data check sum.
CONFIRMATION OF INITIAL DATA
1.
Turn on the POWER, and set to the TV mode.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.
4.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
5.
Press RIGHT/LEFT button to select DATA. When DATA is selected, it will "blink".
6.
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
7.
Pressing RIGHT/LEFT button will take you back to ADDRESS for further selection if necessary.
8.
Repeat steps 4 to 6 until all data has been checked.
9.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
10.
Turn POWER on.
11.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
12.
After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.
All manuals and user guides at all-guides.com

WHEN REPLACING EEPROM (MEMORY) IC

ADDRESS DATA
CRT ON: 00EA
MICON Version
OEC7149A_044
DTV d-h62272
INIT
ROM
VOLUME :343A
ADDRESS DATA
INIT
CRT ON: 00EA
OEC7149A_044
DTV d-h62272
INIT:
ROM:
VOLUME :343A
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
:5DDA
+ (16 x tens digit value)
:0000
+ (ones digit value)
FIG. 1
000
E5
5DDA
0000
FIG. 1
C4-1

Advertisement

Table of Contents
loading

Table of Contents