New Holland SmartTrax T8.320 Service Manual page 63

Hide thumbs Also See for SmartTrax T8.320:
Table of Contents

Advertisement

Pressure control mode
RAIL15TR00370AA
(A) Supply fuel drawn from pre-filter
(B) Supply fuel to final filter
(1) Fuel supply relief valve 5.0 bar (72.5 psi)
(2) Supply pump bypass valve (for bleeding)
Bypass mode
RAIL15TR00370AA
(A) Supply fuel drawn from pre-filter
(B) Supply fuel to final filter
(1) Fuel supply relief valve 5.0 bar (72.5 psi)
(2) Supply pump bypass valve (for bleeding)
Engine - Engine and crankcase
34
35
48123737 21/04/2017
10.1 [10.001] / 24
When the fuel Pressure exceeds 5.0 bar (72.5 psi), the
supply pump relief valve open opens and fuel is routed
to the inlet side of the pump.
During lift pump operation, fuel will bypass the gear
pump through a check valve that opens at about 0.138 –
0.345 bar (2.0 – 5.0 psi).