Sch Det Adjustment (625/50 Mode) - Sony MAV-555 Maintenance Manual

Multi access video disk recorder
Hide thumbs Also See for MAV-555:
Table of Contents

Advertisement

4-4. TM-40 Board Adjustment
8. Turn the SC PHASE knob of a signal generator SG2
slowly in the direction of _90d (2). The vectormoni-
tor waveform at the moment when the oscilloscope
CH-1 waveform appears in field 3, is defined as the
waveform A.
b
B
9. Turn the SC PHASE knob of a signal generator SG2
slowly in the direction of 0d (3). The vectormonitor
waveform at the moment when the oscilloscope CH-1
waveform appears in field 1, is defined as the wave-
form B.
10. Adjust RV1202 and repeat steps 7 through 9 until the
specification [a = b] is satisfied.
11. Return the SC PHASE knob of a signal generator SG2
to the 0d position.
12. Turn the SC PHASE knob of a signal generator SG2
slowly in the direction of _90d (2). The vectormoni-
tor waveform at the moment when the oscilloscope
CH-1 waveform appears in field 3, is defined as the
waveform C.
D
d
13. Turn the SC PHASE knob of a signal generator SG2
slowly in the direction of 0d (3). The vectormonitor
waveform at the moment when the oscilloscope CH-1
waveform appears in field 1, is defined as the wave-
form D.
14. Confirm that [c = d].
4-8 (E)
a
A
C
c

4-4-2. SCH DET Adjustment (625/50 mode)

Preparation
. Connect the black-burst signal "SCH : 0d" to the REF-
ERENCE IN connector on the rear panel.
. Set the setup menu "010-525/625" to "625/50".
n
Refer to the MAV-555 Installation Manual for the
operating procedures.
. Turn off the main power once then back on.
n
To restart quickly, execute the setup menu item [027-
FAST REBOOT].
Connection
SG1 : TSG-130
(TSG-131)
FRAME REF
SG2 : 1410
(1411)
GEN LOCK
CH-2
CH-1
Oscilloscope
A
B
C
D
TP1212
1
1
RV1201
2
3
4
5
6
COMPOSITE
A
Vector
B
Monitor
J1
TP1212
REF
MAV-555
E
F
G
H
TM-40 board (A side)
MAV-555