11. Press the Control switch of the VIDEO PROCESS
block on the meter panel several times until the Local
mode is set.
12. Set all of the four buttons of Video, Chroma, Setup
and Chroma Phase on the meter panel to "PRESET".
13. Confirm that 75% color bar signal is played back.
14. Equipment : Waveform monitor
Test point : ANALOG COMPOSITE MONITOR
OUT (SUPER) connector/rear panel
Adj. point : 1RV1603 (C-6) /EM-1 board
A = 696 ± 3 mV
Spec . :
A
15. Check as follows.
Equipment : Waveform monitor
Test point : CONTROL PANEL (BNC) connector/
rear panel
A = 698 ± 30 mV
Spec. :
A
A
B
C
D
E
1
RV900
1
2
RV1000
1
3
4
5
6
1
RV1603
7
8
MAV-555
F
G
H
J
K
L
EM-1 board (A side)
After Adjustment
1. Set the R1 port and the P1 port of the MAV-555 to the
STOP mode.
2. Return the setup menu "010-525/625" to the same
setting as that before adjustment.
3. Return the switch of the VIDEO PROCESS block on
the meter panel to the same setting as that before
adjustment.
4. Turn off the main power of the MAV-555.
4-2. EM-1 Board Adjustment