Relative Leak Size Indication; Audio Mute Function; Leak Tracing Function - Bosch CS LD 1.0 Operator's Manual

Refrigerant leak detector
Hide thumbs Also See for CS LD 1.0:
Table of Contents

Advertisement

Available languages

Available languages

can be repeated as many times as
necessary. Refer to Section 6.1.2
Automatic and Manual Reset Mo-
des for more details on resetting
the unit
.
7. A suspected leak should always
be verified by resetting the unit
in fresh air by moving away
from source and back again.
6.3
Relative leak size
indication
The leak size indicator (rings)
remains off normally but once a
leak is detected, a number of rings
will be displayed. The number will
continue to increase or decrease
depending on the amount or con-
centration of refrigerant sensed.
The Leak Size Display is a relative
size indicator; i.e. 2 rings indicates
a larger concentration than 1 ring,
3 rings a larger concentration than
2, etc.
Because the CS LD 1.0 is a broad-
band detector, intended for use on
a very wide range of compounds,
it is not to be considered as a
measurement device. The sensiti-
vity to different compounds varies,
therefore the rings cannot reliably
be used to indicate a specific con-
centration or leak size.
Bosch Automotive Service Solutions GmbH
Operating Instructions | CS LD 1.0 | 39 | en
6.4
To silence or mute the audio beep
and alarm signal, press the Audio
ON/OFF button (See Fig 8a). The
display will show the speaker icon
muted (See Fig 8b). In the event of
an alarm, a "bell" icon (Fig 8c) will
be displayed along with the relative
leak size indicator. To restore the
audio sound, press the Audio ON/
OFF button again.
8a
Fig. 8:
i i
A few seconds is required to
restore sound if the Audio ON/
OFF button is pressed in rapid
succession.
6.5
To enter the Leak Tracing Mode,
press the Graph button Item 7, Fig
1.1. This mode allows the user to
pinpoint hard to find small leaks.
The display "cursor" will move
from left to right tracking the sen-
sor output. The graph's horizontal
axis (x-axis) represents a timeline
from 0 to 8 seconds; the verti-
cal axis (y-axis) indicates signal
change intensity.
When no refrigerant is sensed, the
baseline trace will be flat. While
searching, if refrigerant is sensed,

Audio mute function

8b
8c
Audio Icons

Leak tracing function

|
F 002 DG9 H12
2021-04-08