INTRODUCTION Attention: Read through the complete manual prior to the initial use of your pressure washer. Using the Operator's manual The operating manual is an important part of your pressure washer. It should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed.
PRODUCT IDENTIFICATION IIf you need to contact an Authorized Dealer or Customer Service line ((02 4577 2144) for information on servicing, always provide the product You will need to locate the model and serial number for the machine and record the information in the places provided below. Date of Purchase: Dealer Name: Dealer Phone:...
SAFETY IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING - When using this product, the following precautions should always be observed and adhered to. 1. Read all instructions before using the product. 2. To reduce the risk of injury, close supervision is necessary when a product is used near children.
SAFETY - COOLING INFORMATIONY Motors are air cooled. It is important to ensure that machine is operated in a well- ventilated area where it can draw a steady supply of fresh air. The arrows below show an example of locations for air intake on an engine. Pumps are water cooled.
SAFETY SAVE THESE INSTRUCTIONS Safety Rules This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards.
Page 9
SAFETY WARNING explosive. Fire or explosion can cause severe burns or death. When Adding or Draining Fuel • Turn pressure cleaner OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank. •...
Page 10
SAFETYY WARNING A running engine gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide can cause headache, fatigue, dizzi- ness, vomiting, confusion, seizures, nausea, fainting or death. Some chemicals or detergents may be harmful if inhaled or ingest- ed, causing severe nausea, fainting, or poisoning.
Page 11
SAFETYY WARNING Use of pressure cleaner can create puddles and slippery surfaces. Kickback from spray gun can cause you to fall. • Operate pressure cleaner from a stable surface. • The cleaning area should have adequate slopes and drainage to reduce the pos-sibility of a fall due to slippery surfaces.
Page 12
SAFETY WARNING The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury. •...
Page 13
SAFETY WARNING When Adjusting or making Repairs to Your Pressure Washer Cleaner • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. When Testing for Engine Spark • Use approved spark plug tester. •...
120 BAR4013-HJ The following diagram is intended for general reference. Black Detergent Red Straight Your pressure cleaner may differ from the model shown below. For Yellow 15 specific model information, please visit www.bargroup.com.au. White 40 Spray Gun / Lance Assembly - Controls the application of water onto cleaning surface with trigger device.
Page 15
120 BAR3513G-HJV The following diagram is intended for general reference. Black Detergent Your pressure cleaner may differ from the model shown below. For Red Straight specific model information, please visit www.bargroup.com.au. Yellow 15 White 40 Spray Gun / Lance Assembly - Controls the application of water onto cleaning surface with trigger device.
Page 16
120 BAR3513G-HJVT The following diagram is intended for general reference. Black Detergent Red Straight Your pressure cleaner may differ from the model shown below. For Yellow 15 specific model information, please visit www.bargroup.com.au. White 40 Spray Gun / Lance Assembly - Controls the application of water onto cleaning surface with trigger device.
ASSEMBLY Your pressure cleaner requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel. We recommend SAE 10W30 Oil for engines. SAE 90 Gear Oil for gearbox units and Universal Tractor Transmission Oil for pump. See page 5. If you have any problems with the assembly of your pressure cleaner, please call our support line.
PRE-OPERATION CHECKLIST Follow the steps below prior to using the machine every time. 1. Check to ensure the engine oil is at the proper level. Use SAE 10W30 Oil. Check the handle in the frame to ensure they are tight and will not vibrate loose.
STARTING YOUR CLEANER How to Start Your Pressure Cleaner To start your pressure cleaner for the first time, follow these instructions step- by-step. This starting information also applies if you have let the pressure cleaner sit idle for at least a day. 1.
Page 20
STARTING YOUR CLEANER 5. If your gun uses a quick-connect, pull down on the collar of the quick connect coupler, slide onto the gun and let go of collar. Pull on hose to thread the connections together until secure. WARNING The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and...
Page 21
STARTING YOUR CLEANER 9. To start the machine, locate the engine switch on the side of the engine (if applicable), and switch it to the ON position. Units with a Honda GC engine have the power switch built into the throttle lever. Check to ensure fuel valve is in the position and if starting cold, apply the choke.
Page 22
STARTING YOUR CLEANER WARNING The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
SHUTTING DOWN YOUR CLEANER WARNING Exhaust heat/gases can ignite combustibles, structures or damage • DO NOT touch hot parts and avoid hot exhaust gases. • Allow equipment to cool for at least 15 minutes before touching. • Keep at least 5 feet (1.5 m) of clearance on all sides of pressure cleaner (including overhead) while in operation.
ELECTRIC START OPTIONS The following diagram is intended for general reference. Your pressure cleaner may differ from the model shown below. For specific model information, please visit www.bargroup.com.au. Location 1 Location 2 Location 3 Location 1: Battery is placed on the back of the panel. Location 2: Battery is placed on the hanger which is bolted to the panels.
SPRAY TIPS soaper WHITE BLACK YELLOW How to Use Spray Tips The quick-connect on the nozzle extension allows you to switch between four different quick connect spray tips. Spray tips can be changed while the pressure cleaner is running once the spray gun trigger safety lock is engaged. The spray tips vary the spray pattern as shown above.
To apply detergent, follow these steps: 1. Review the use of spray tips. 2. Prepare detergent solution as required by the job. See your BAR shop for detergent options. 3. Place the small filter end of detergent siphoning tube into detergent container or on- board soap tank (if applicable).
TROUBLESHOOTING Troubleshooting Chart If you are experiencing an issue that is not listed in this chart, or have checked all the possible causes listed and are still experiencing the problem, see your authorized dealer or call our support line. PETROL ENGINES Problem Cause Correction...
TROUBLESHOOTING PUMP Problem Causes Correction No low pressure Using wrong nozzle Insert black soaper nozzle detergent delivery Clear siphon hose of debris Unit does not reach Check supply hose, faucet and inlet Unsuitable or worn out nozzle required pressure Regulator set too low (for units with source that provides at least 6 GPM an adjustable unloader) Replace nozzle...
STORAGE Thermal Relief Valve Water temperature is too high Use cool water only. is open and discharg- Pump has operated more than Pull trigger at least 30 seconds ing water from side 3 mins without pulling trigger every 3 mins. Thermal valve must of pump be replaced.
STORAGE When fuel stabilizers are used according to their instructions, there is no need to drain the petrol from the engine prior to storage. Run the engine for a short time to circulate stabilizer throughout the fuel system. Engine and fuel can then be stored for up to 24 months.
PARTS LIST Major Components P/N: 120 BAR4013-HJ If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 33
Major Components P/N: 120 BAR4013-HJ If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line.
Page 34
PARTS LIST Major Components P/N: 120 BAR4013-HEJ If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 35
Major Components P/N: 120 BAR4013-HEJ If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line. See page 24 for other battery types &...
Page 36
PARTS LIST Major Components P/N: 120 BAR3513G-HJV If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 37
Major Components P/N: 120 BAR3513G-HJV If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line.
Page 38
PARTS LIST Major Components P/N: 120 BAR3513G-HEJV If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 39
Major Components P/N: 120 BAR3513G-HEJV If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line. See page 24 for other battery types &...
Page 40
PARTS LIST Major Components P/N: 120 BAR3513G-HJVT If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 41
Major Components P/N: 120 BAR3513G-HJVT If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line.
Page 42
PARTS LIST Major Components P/N: 120 BAR3513G-HEJVT If you want to reorder parts when damaged or not functioning, refer to the diagram below with parts tables on next page. If still not found, see your authorized dealer or call our support line.
Page 43
Major Components P/N: 120 BAR3513G-HEJVT If you want to reorder parts when damaged or not functioning, refer to the parts tables below with diagram on previous page. If still not found, see your authorized dealer or call our support line. See page 24 for other battery types &...
Shipping All products from BAR are supplied ex-Works our nearest warehouse. Where BAR agree to pay the freight for any shipment, this does not change the ex- works terms. We strongly recommend you undertake transit insurance for all shipments.
Our representations relate solely to the operating performances of the product (in isolation to the application). Reservation of Title The rights to, and full interest and title in the goods supplied remains with BAR and does not pass to you until the goods have been fully paid for.
Page 47
If you need assistance with the assembly or operation of your Pressure Cleaner please contact 02 4577 2144 sales@bargroup.com.au August 2021...
Need help?
Do you have a question about the BAR4013-HJ and is the answer not in the manual?
Questions and answers