Resistance
The maximum temperature of the pumped liquid should not exceed +35 ℃ in continuous oper-
ation.
The transport of aggressive fluids (acids, bases, etc.) as well as of abrasive substances (for
example sand) must be avoided.
Electrical connection
The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse min. 6 A.
The motor is protected from overcharge and blockage with the help of the built-in thermal motor
protection. When overheated, the pump motor is automatically switched off by the thermal pro-
tection; after cooling down, the pump automatically re-starts.
Mains connection
The pond pump that you have purchased is already equipped with a protection plug. The pump is meant
to be connected to a 220/230 V~50 Hz safety socket. Make sure that the socket is sufficiently protected
(min. 6 A) and fully functional. Plug in the plug, the pump is operational.
Note:
Installation
Place the pump beneath the water surface, making sure that no water can penetrate into the socket.
The pump is installed the following way: either in a stationary position with a fixed pipeline or in a sta-
tionary position with a flexible pipeline.
Use as submerged pump (see Fig. 1)
Submerge the pomp completely into the pond to allow it to fill with water.
In order to protect the pump from obstruction, place it above the pond mud.
In case a filter sponge is included, install it in order to keep the intake of the pump free.
The pump is operated by plugging the plug in the socket.