WilTec SunSun CET-8000 Operation Manual

WilTec SunSun CET-8000 Operation Manual

Adjustable supereco pond pump

Advertisement

Operation Manual
Adjustable SuperECO pond pump
SunSun CET-8000
50982
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignific -
antly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Advertisement

Table of Contents
loading

Summary of Contents for WilTec SunSun CET-8000

  • Page 1 Operation Manual Adjustable SuperECO pond pump SunSun CET-8000 50982 Illustration similar, may vary depending on model Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps and technical data can differ insignific - antly.
  • Page 2 All rights reserved. The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown.
  • Page 3: Using Application

    Super silence, usable both in fresh and sea water  New and generous design, rotary handle, easy to carry  Rotary footings, can work both vertical or horizontal  © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 3 http://www.WilTec.de http://www.aoyue.eu 2020-1...
  • Page 4: Installation

    5. Do not place the pump directly in muddy pond floors, place it on a raised surface. 6. Connect the pump with the controller of four core wire (PIC 1), lock the nut as shown in PIC 2. © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 4 http://www.WilTec.de...
  • Page 5: Controller Unit

    2000 l SP04 5000 2600 l SP05 5400 3200 l 50982 110V~22V (CET-8000) 50~60HZ SP06 5800 3500 l SP07 6200 3800 l SP08 6700 4500 l SP09 7200 4800 l SP10 8000 5100 l © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 5 http://www.WilTec.de http://www.aoyue.eu 2020-1 http://www.teichtip.de...
  • Page 6 Pump works without water Abnormal Check the pump if working without water ER02 Pump block Abnormal Check the impeller if blocked ER01 Over-/undervoltage display Abnormal Check voltage © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 6 http://www.WilTec.de http://www.aoyue.eu 2020-1 http://www.teichtip.de...
  • Page 7: Maintenance & Cleaning

    After that, dry it and keep it in a secure place. If the temperature is below 0°C, the water in the pump should be discharged immediately in order to prevent a freezing damage. © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 7 http://www.WilTec.de...
  • Page 8: Troubleshooting

    Bottom foot Ceramic bearing Filter case Motor with cable Outlet Rear cover Seal circle Handle Impeller cover Rubber foot Rotor set Gear box with cable O-Ring © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 8 http://www.WilTec.de http://www.aoyue.eu 2020-1 http://www.teichtip.de...
  • Page 9: Disposal Regulations

    All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
  • Page 10: Eg-Konformitätserklärung

    It has been tested with the following harmonised standards: Il a été testé à partir des normes harmonisées suivantes : EN 60335-2-41:2003+A1:2004+A2:2010 EN 60335-1:2012+A11:2014 EN 62233:2008 Eschweiler, 30. August 2015 __________________________ Bernd Wildanger Geschäftsführer © by WilTec Wildanger Technik GmbH Artikel 50982 Seite 10 http://www.WilTec.de http://www.aoyue.eu 2020-1 http://www.teichtip.de...