Main Components
Fig. 1.1
1 – Keypad, 2 – Folding handle, 3 – Green LED [G],
4 – Red LED [R], 5 – Plastic cover for emergency power
2
Definitions
2.1
Master Code [PIN1]
A set of numbers (from 6 to 8 digits) which
opens the lock and allows to operate the settings.
Before using the safe, please change the factory
Master
code
(see
par.4.1).
recommended to keep the master code safe from
unauthorized people.
No easily guessed numbers (birthdays, house and
phone numbers, etc.) or simple codes (1, 2, 3, 4, 5,
6) shall be chosen for the coding.
Safe Digital Lock
Factory Master Code:
1–2–3–4–5–6
2.2
User Code [PIN2]
A set of numbers from 6 to 8 digits which opens
the lock and has limited functions to change the
settings.
The lock with the default factory settings does not
have the User code. Please see par.4.2 to set the
User code.
2.3
Signals
1
[
G]
green LED flash (3) – confirmation of the button
pressing on the keypad.
2
[
G]
green LED flash (3) – confirmation of successfully
finished operation.
[
R]-- Long single acoustic signal with single
red LED flash (4) – error message on the user's
actions.
5
[
R]
5 red LED flashes (4) – low battery message. Please
see par.5.1 how to change the battery
3
Main Functions
3.1
Opening the Lock
3.1.1
Opening with the Factory Master code
[ON][1][2][3][4][5][6][Enter]
3.1.2
Opening with the Master Code
[ON][PIN1][Enter]
3.1.3
Opening with the User Code
It
is
strongly
[ON][PIN2][Enter]
PS310/E01, PS310/ES01, PS310/E02
Short single acoustic signal with single
Short double acoustic signal with double
Short acoustic signal sounds 5 times with
.
www.promet-safe.com
If the code is right, there will be a green LED
flash and it will be possible to open the door within 5
seconds by turning the handle (2) clockwise.
If you enter a wrong code three times in a row, the
lock will be blocked for 5 minutes. The blocking of the
lock will be indicated periodical red LED flashes.
3.2
Closing the Lock
Close the door and turn the handle (2) anti-
clockwise until it stops.
4
Service Functions
It is strongly recommended to change the settings of
the lock with the door opened.
After code changing, the lock shall be tested several
times with the secure storage unit's door in open
state.
The service functions will be unavailable in case low
power supply which is indicated by the signals,
5
please refer to par.2.3, [R]
.
4.1
Changing the Master Code [PIN1]
[ON] [Enter] [1] [Enter] [PIN1] [Enter]
[new PIN1] [Enter]
[repeat new PIN1] [Enter]
Checking the new Master code:
[ON][new PIN1][Enter]
4.2
Setting and changing the User Code [PIN2]
with the Master Code [PIN1]
Before changing the User Code [PIN2] default factory
setting of Master code [PIN1] have to be changed
(see par.4.1).
[ON][Enter][2][Enter]
[1-9 (user number)][Enter][PIN1][Enter]
[new PIN2][Enter]
[repeat new PIN2] [Enter]
Checking the new User Code:
Ver. 1/3 15.02.2019
USER MANUAL

Advertisement

loading

Summary of Contents for Promet PS310/E01

  • Page 1 Safe Digital Lock PS310/E01, PS310/ES01, PS310/E02 USER MANUAL Factory Master Code: If the code is right, there will be a green LED 1–2–3–4–5–6 flash and it will be possible to open the door within 5 seconds by turning the handle (2) clockwise.
  • Page 2 Safe Digital Lock PS310/E01, PS310/ES01, PS310/E02 USER MANUAL [ON][new PIN2][Enter] Dual Code Function Changing the User Code [PIN2] without the Switching on the Dual Code function Master Code Before switching on the function, make sure you [ON][Enter][3][Enter] have assigned a User Code [PIN2] see par.4.2.

This manual is also suitable for:

Ps310/es01Ps310/e02