Chapter 2 Product Installation ............................5 2.2 Connector ................................. 5 2.2 CAN bus connections .............................. 6 2.3 Configing and Using the CANFDNET-100T/200T ....................7 2.3.1 Introduction for the Config software and parameters................. 7 2.3.2 Using the CANFDNET-100T/200T ........................ 8 Chapter 3 Application Software development .......................
TCP/IP protocol and supports one or two CAN (FD) channel. Using this module will enable PC to connect to CAN-bus network via Ethernet bus. CANFDNET-100T/200T module comes with an electrical isolation module, which could be used to avoid the damage caused by the ground loop and enhance the system reliability when working under a tough environment.
1.5 Product Sales list [1] CANFDNET-100T/200T Isolated CAN(FD) to Ethernet Converter; [2] CD-ROM.(Datasheet, CANFDNET-100T/200T config and test software) Contact: sales@buenoptic.net...
2 Product Installation Chapter 2.2 Connector CANFDNET-200T module integrates two CAN-bus channels, while CANFDNET-100T integrates one. The pin signal definitions see Figure 2-1, and Table 2-1. Figure 2-1 : CANFDNET-100T/200T CAN interface module Contact: sales@buenoptic.net...
2-4). 2.2 CAN bus connections To connect CANFDNET-100T/200T module to the CAN-bus, user only need to connect CAN_H and CAN_L, CAN-bus network adopts straight-line topology, and two terminal 120Ω resistances need to be installed on the two bus terminals. If the number of odes larger than 2, the 120Ω resistance is not necessary to be installed on the middle node.
Port of UDP protocol of host HostUdpPort IP Address of the device (CANFDNET-100T/200T module), which you want to DeiveIP setup Port of UDP protocol of the device (CANFDNET-100T/200T module) , which you DevieceUdpPort want to setup (3)Main View ->Setup->CAN0 or CAN1 Arbitrate Arbitrate baud rate(the maximum is 1M )...
2.3.2 Using the CANFDNET-100T/200T Modify the IP address of the PC so that the CANFDNET-100T/200T module and PC are on the same network segment. Power the CANFDNET-100T/200T module with a DC of 10-30V. Insert the LAN cable into the plug labeled LAN and connect it either to a hub or switch, or directly to the PC using a crossover cable.
www.buenoptic.net 3 Application Software development Chapter 3.1 Communication Protocol 69 Bytes Frame info Frame ID Frame Data 1Byte 4 Byte 64 Bytes Figure 3-1: CAN packets in UDP Frame : 1) Frame Info Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 DLC3 DLC2...
Page 10
www.buenoptic.net Figure 3-2 Data length of CAN(FD) ) ID of the frame A example of ID=0x3FF Another example of ID=0x12345678 ) D ata The data part has 64 bytes. A can frame can contain up to 8 bytes of data, and the insufficient bytes are supplemented by 0;...
Page 11
11 22 33 44 55 66 77 88 11 22 33 44 55 66 77 88 11 22 33 44 55 66 77 88 11 22 33 44 55 66 77 88 11 22 33 44 55 66 77 88 ) N ote When you send the UDP packet from PC to CANFDNET-100T/200T module, the max number of Contact: sales@buenoptic.net...
Page 12
www.buenoptic.net CAN(FD) packets in every UDP packet is 10. In addition, when you finish sending a UDP packet including 10 CAN(FD) packet, you should delay some time according the baud rate which you set. Contact: sales@buenoptic.net...