3.1.3 Normal mode displays

Normal mode displays, which show lubrication program set values, can be browsed with
-button.
Display codes change in the following order when
Display code
CH
Cou
C
P
PLo
PHi
dEL
HL
Decimal points are used to separate thousands in lubrication cycle counter reading. Counter
max. reading is 49.9 = 49 999.
According to lubrication system basic settings pressure unit on the display is bar or psi. In psi –
reading decimal points are used to separate thousands. For example 1.02 = 1020 psi.

3.1.4 Line pressure displays

Pressure transmitter operation
In pressure transmitter operation, line pressure displays can be selected with
Pressing the button will show the line 1 pressure display first. Code P1 and line 1 pressure
display are displayed in turns. Pressing the button again will show the line 2 pressure display.
Code P2 and line 2 pressure display are displayed in turns. If line 2 does not exist, program
returns to display the phase code. From line 2 pressure display program returns to display
phase code by pressing
after 4 minutes if the buttons have not been used.
If signal from pressure transmitter is not detected code _ _ _ is displayed.
MUIF3AEN.doc
MAXILUBE
IF-105
Description
The lubrication channel selected on the display. Code is used only
in a system with two channels. Press SET-button to move to
another channel when the code is displayed.
(Channel)
Lubrication cycle counter
(Cycle Counter)
Lubrication cycle set value [h.mm]
(Lubrication Cycle)
Maximum pressurization time set value [s]
(Lubrication, Pressurization time)
Set value can be changed to minutes with factory setting parameter
Prt.
Low limit pressure set value [bar/psi]
(Pressure, Low limit)
Code is used only in pressure transmitter operation.
High limit pressure set value [bar/psi]
(Pressure, High limit)
Code is used only in pressure transmitter operation.
Pressure discharge delay multiplier [n]
(DELay) Delay = P * n [s]
Code is used only in pressure switch operation.
Manual operation setting
On: manual operation mode
OFF: automatic operation mode
-button. The display returns to display the phase code automatically
-button is pressed.
5 (9)
-button.
21.4.2005 Rev. 3A