Phase Codes For Normal Mode And Alarm Mode - SAFEMATIC MAXILUBE IF-105 Manual

Table of Contents

Advertisement

3.1.2 Phase codes for normal mode and alarm mode

In normal or alarm mode, the phase code corresponding to the program phase is shown on the
display.
Phase code
dC
Loc
OFF
AGr
ALP
AHP
AIn
Air
MUIF3AEN.doc
Description
Pressure discharge waiting time
(disCharge)
Interlocking switch is closed
(Locked)
The channel is closed
Lubricant barrel low level alarm
(Alarm, Grease)
Pressure low alarm
(line pressure does not rise high enough during pressurization time)
(Alarm, Low Pressure)
Pressure high alarm
(line pressure is not low enough when pressurization phase starts)
(Alarm, High, Pressure)
Alarm from LG-ind doser operation indicators.
Code is used only if LG-ind doser operation indicators are in use.
(Alarm, Indicator)
Alarm from air pressure switch of grease spray system.
Code is used only if air pressure switch is in use.
(Alarm, Air)