1-1-2. Preparation before Adjustment
<Opening the CCU>
1. Remove all cables connected to CCU.
2. Remove one scrwe (2) fixing the unit cover
(1).
Fig. 5
3. Turn over the unit.
4. Remove four screws (3) fixing the unit cover
(1).
5. Pull the mechanical chassis (4) in the arrow
direction.
(3)
(4)
Fig. 6
1-1-3. Equipment Connection Diagram
Lens
(2)
(1)
(3)
1-1-4. Initial Setting
(1)
Note: Perform the adjustments in a location with less
2-2
Camera
Camera control unit
head
Waveform monitor (WFM)
9
75
termination
Fig. 7
1. Perform the warming up for approx. 5 min-
utes with the POWER switch turned "ON"
before performing the adjustments.
2. When the chart is illuminated unevenly, the
correct adjustment cannot be performed. So
set the light equipments to give an even
illumination.
dust to prevent inside of the camera head from
dirty.
VIDEO
DC IN12V
DC power supply
Vector scope
Color monitor