  • Page 1 Back to Disk Menu Park Air T6MC Controller User Documentation...
  • Page 2: Foreword

    Similarly, any trademarks and protected names or symbols contained in this documentation, or associated documentation, are the property of their respective holder. Handbook Title: Park Air T6MC Controller User Documentation Handbook Part Number: 31-3600T6MC Handbook Version:...
  • Page 3: Configuration Page

    Back to Disk Menu Configuration Page This user documentation is applicable only to Park Air T6MC controllers that are configured as per the information given on this page. Park Air T6MC Controller Configuration for the Park Air T6MC controller applicable to this user documentation is listed in...
  • Page 4: Modifications

    Back to Disk Menu Modifications Modifications (Build State) to the Park Air T6MC controller are listed below. Applicable Modification Date Detail Park Air State Change Notice 5 April 2001 RLB added to allow both 2-wire and 4-wire working 6 October 2003...
  • Page 5: Health And Safety

    Park Air T6MC Controller The Park Air T6MC controller operates from a low voltage dc input supply, or a standard mains ac input supply. When using a mains supply, dangerous voltage is present on the rear panel ac connector and within the equipment.
  • Page 6: Customer Support

    To ensure the highest level of after sales service, it is necessary to gather as much information as possible about equipment faults. If any equipment supplied by us becomes unserviceable, please complete a copy of the fault report shown on the next page, and return it to the Customer Services department. Park Air T6MC Controller Page vi...
  • Page 7 ............Park Air T6MC Controller...
  • Page 8: Approvals And Regulations

    Back to Disk Menu Approvals and Regulations The following approvals and regulations apply to the Park Air T6MC controller. Approvals The equipment is designed to meet the essential requirements of the following Directives: 99/5/EC Radio Equipment and Telecommunications Terminal Equipment Directive (R&TTE) ...
  • Page 9 Date: 30 August 2012 N. Upton - Technical Director Certificate No. BT6MC-002 Park Air Systems Ltd Registered in England 1951792 Registered Office: Northfields, Market Deeping, Peterborough, PE6 8UE, UK. A subsidiary of Northrop Grumman Corporation. Park Air T6MC Controller Page ix...
  • Page 10: Glossary Of Terms

    Mutes a receiver’s audio output during periods of no reception  Mutes a receiver’s audio output when signals weaker than the squelch threshold are received.  Phantom Keying Phantom keying is when the keying potential is superimposed on the audio lines. Park Air T6MC Controller Page x...
  • Page 11: Abbreviations

    RCMS remote control and monitoring hertz system intermediate frequency reference internet protocol radio frequency kilo RF PA radio frequency power amplifier kbits/s kilobits per second RSSI radio signal strength indication Park Air T6MC Controller Page xi...
  • Page 12 VCCS voice control and communication switch virtual front panel very high frequency VOGAD voice-operated gain adjusting device VoIP voice over internet protocol VSWR voltage standing wave ratio watt wideband waveform profile Park Air T6MC Controller Page xii...
  • Page 13: Table Of Contents

    Operation Controls, Indicators and Front Panel Connector Front Panel Volume Control Intercom Switch Busy Indicator Supply Indicator Microphone Connector Rear Panel Controls and Connectors Power Switch ac Input Connector ac Voltage Selector Facilities Connector Park Air T6MC Controller Page xiii...
  • Page 14 Introduction Power Supplies ac Operation dc Operation Receive Operation Loudspeaker Switching Transmit Operation PTT Operation Audio Routing Intercom Switching Fault Finding Parts List Introduction Part Numbers Hardware Configuration Parts Listing Figures List of Figures Park Air T6MC Controller Page xiv...
  • Page 15: Introduction

    Back to Disk Menu Introduction...
  • Page 16 Back to Disk Menu Introduction The Park Air T6MC controller provides a remote operating position for Park Air radios. The controller can be sited up to 1 km from the controlled equipment. At the controller transmissions are made using a microphone, with integral PTT switch, plugged into the front panel;...
  • Page 17: About This Documentation

    7-2. The keying potential is superimposed on the transmit audio lines to provide phantom PTT. An intercom facility is available from the controller's front panel. This facility allows an operator to speak to other controllers without keying the transmitter. Park Air T6MC Controller Page 1-3 Introduction...
  • Page 18: Models And Part Numbers

    Back to Disk Menu Models and Part Numbers Table 1-1 details the T6MC controllers covered in this user documentation and lists the part numbers. Table 1-1 Models and Part Numbers Model Park Air Part Number Park Air T6MC desktop controller...
  • Page 19: Specification

    Back to Disk Menu Specification...
  • Page 20: Dimensions And Weight

    220 mm Height 112 mm Depth 165 mm Weight 1.5 kg (3.31 pounds). The dimensions and weight of the Park Air T6MC rack mount controllers are: Width 483 mm Height 88 mm Depth 159 mm excluding handles. 199 mm including handles Weight 3 kg (6.61 pounds) (rack with two controllers fitted)
  • Page 21: Circuit Properties

    Phantom keying via line transformer centre-tap. Alternative keying method External PTT (0 V discrete signal). Optional Connections to an External Tape Recorder Tape recorder Transmit/receive single-ended audio connection at a maximum level of 6 V peak-to-peak. Park Air T6MC Controller Page 2-3 Specification...
  • Page 22 Back to Disk Menu Intentionally Blank Park Air T6MC Controller Page 2-4 Specification...
  • Page 23: Operation

    Back to Disk Menu Operation...
  • Page 24: Controls, Indicators And Front Panel Connector

    Back to Disk Menu Controls, Indicators and Front Panel Connector This topic describes the Park Air T6MC controller’s controls, indicators and front panel connector. Front Panel The controller’s front panel is illustrated below. Volume Control A rotary control used to adjust the volume of the internal loudspeaker.
  • Page 25: Microphone Connector

    Not connected Sidetone and receiver Output Maximum 6 V peak-to-peak audio monitor Microphone audio Input Passive microphone Ground Pin-out of the Microphone connector looking into the mating face of the chassis mounted socket. Park Air T6MC Controller Page 3-3 Operation...
  • Page 26: Rear Panel Controls And Connectors

    FACILITIES AC INPUT DISCONNECT FROM MAINS WHEN NOT IN USE Fig 3-1 T6MC Controller Rear Panel Power Switch WARNING Dangerous Voltage When the Power switch is set to the Standby position, dangerous voltage is still present in the controller's internal power supply circuitry. To ensure safe working during maintenance, the controller must be isolated from the ac and dc input supplies.
  • Page 27: Ac Voltage Selector

    Before using this optional facility, link LK3 must be removed from the controller's PCB (see 7-7). Tape/sidetone Output Single-ended audio connection at a maximum level of 6 V peak-to-peak. The output is both transmit and receive audio. Park Air T6MC Controller Page 3-5 Operation...
  • Page 28: Setting Up And Operation

    To speak to other positions, press down the Intercom switch, then press the microphone's PTT switch and speak into the microphone. When finished, release the microphone's PTT switch, and then release the Intercom switch. Park Air T6MC Controller Page 3-6 Operation...
  • Page 29: Installation

    Back to Disk Menu Installation...
  • Page 30: Introduction

    Connecting a tape output (if required) page 4-5 Connecting an external cradle switch (if required) page 4-5 Connecting the ac input supply (if required) page 4-6 Connecting a microphone to the controller page 4-6 Park Air T6MC Controller Page 4-2 Installation...
  • Page 31: Checking The Installation Materials

    Back to Disk Menu Checking the Installation Materials The Park Air part number for the T6MC controller is BT6MC and the Park Air part number for the T6MC rack mount controller is 70-T6MCRACK. The items listed in Table 4-2 are included under these part numbers.
  • Page 32: Connecting The Controller To T6 Radios

    Braid Fig 4-1 Cable Screen Connection to D-Type Plug's Shell Connecting Controllers in Parallel Up to four T6MC controllers can be used in parallel with T6 radios. Two controllers connected in parallel are shown in Fig 7-1 (no phantom keying) or Fig 7-2 (with phantom keying).
  • Page 33: Connecting The Dc Input Supply

    Facilities connector (CN1) pin 15. Connecting an External Cradle Switch A hand microphone is supplied as part of the standard T6MC controller installation. A telephone type handset can be used instead of the standard microphone. The telephone type handset normally rests on a cradle when not in use;...
  • Page 34: Connecting The Ac Input Supply

    Between 220 Vac and 240 Vac the selector must be set to 220.  The T6MC controller is a class 1 equipment. The ac supply cable must have a green-and-yellow protective earthing conductor electrically connected to the protective earthing terminal of the equipment connector and the supply output connector.
  • Page 35: Maintenance

    Back to Disk Menu Maintenance...
  • Page 36: Introduction

    7-7. Power Supplies The T6MC controller operates from either an ac input supply between 110 and 120 Vac, or 220 and 240 Vac. Alternatively, the controller can be used with a dc input supply between 21.6 and 32 Vdc. When both ac and dc input supplies are connected, the controller continues to operate using the dc supply if the mains supply fails.
  • Page 37: Transmit Operation

    Audio is therefore routed to the parallel connected controllers, but no PTT signal is sent. Use of the Intercom facility does not inhibit the External PTT signal. The intercom cannot therefore be used when an External PTT signal is connected to the transmitter. Park Air T6MC Controller Page 5-3 Maintenance...
  • Page 38: Fault Finding

    Table 5-1 provides information on typical conditions that may be expected at selected points in the circuit with the equipment functioning normally and under the test conditions indicated. Table 5-1 T6MC Controller Circuitry - Typical Conditions Measurement Function Test Conditions...
  • Page 39: Parts List

    Back to Disk Menu Parts List...
  • Page 40: Introduction

    Back to Disk Menu Introduction All parts for the Park Air T6MC controller are available as individual spares. Users should note any listed spare that has an ‘S’ at the end of the part number is Safety Critical. For example, rear panel fuse F1: 20 mm, 63 mA anti-surge 29F01480102S Safety critical means that only the exact part, as supplied by Park Air, should be fitted in this equipment.
  • Page 41 59-15605002 Resistor, 560k, 1%, 0.25 W, metal film 59-11502003 Resistor, 150R, 1%, 0.6 W, metal film 59-10105003 Resistor, 10k, 1%, 0.6 W, metal film 59-11005003 Resistor, 100k, 1%, 0.6 W, metal film Park Air T6MC Controller Page 6-3 Parts List...
  • Page 42 Back to Disk Menu T6MC Controller Components (continued) Reference Part Number Description Notes 59-10225003 Resistor, 22k, 1%, 0.6 W, metal film 59-10105003 Resistor, 10k, 1%, 0.6 W, metal film 59-10105003 Resistor, 10k, 1%, 0.6 W, metal film 59-10105003 Resistor, 10k, 1%, 0.6 W, metal film 59-10275002 Resistor, 27k, 1%, 0.6 W, metal film...
  • Page 43 Back to Disk Menu T6MC Controller Components (continued) Reference Part Number Description Notes 14-36226101 Capacitor, tantalum, 2.2µF, 35 V, 20% 14-36226101 Capacitor, tantalum, 2.2µF, 35 V, 20% 14-21105200 Capacitor, plastic, 100nF, 63 V, 5% 14-03153301 Capacitor, ceramic, 1.5nF, 100 V, 10%...
  • Page 44 Back to Disk Menu T6MC Controller Components (continued) Reference Part Number Description Notes 61-00320005 Bridge rectifier, W005 61-00314004 Diode, IN4004 61-00104148 Diode, IN4148 61-00104148 Diode, IN4148 61-00505551 LED, red 61-12003240 Integrated circuit, dual op amp, 3240 61-12001458 Integrated circuit, dual op amp, 1458G...
  • Page 45 Back to Disk Menu T6MC Controller Components (continued) Reference Part Number Description Notes Fuses: 29-01050101 Fuse, 20 mm, 500 mA 29-01060101 Fuse, 20 mm, 1 A 29F01480102S Fuse, 20 mm, 63 mA anti-surge (for 220/240 V range) 29F01490102S Fuse, 20 mm, 125 mA, anti-surge (for 110/120 V range)
  • Page 46 Back to Disk Menu T6MC Rack Mount Kit Reference Part Number Description Notes 46-00000178 Front panel 46-00000179 Cover 2 off 46-00000180 Bracket 2 off 46-00000181 Front panel brace top 46-00000182 Front panel brace bottom 46-00000209 Blanking plate 45E00010387 Unit handle...
  • Page 47: Figures

    Back to Disk Menu Figures...
  • Page 48: List Of Figures

    Back to Disk Menu List of Figures Fig 7-1 T6MC Controller to T6 Radio Configurations (With External PTT) Fig 7-2 T6MC Controller to T6 Radio Configurations (With Phantom Keying) Fig 7-3 T6MC Controller Enclosure Fixing Detail Fig 7-4 T6MC Rack Mount Controller Fitting Details...
  • Page 49 Connections required to connect two controllers in parallel T6MC Controller 4 Facilities Connector Optional controllers T6MC Controller T6TR Transceiver Table 7-1 T6MC Controller to T6 Radio Connections (With External PTT) 5 + Ground Facilities MARC Audio TX/RX Antenna T6MC Controller T6 Radio...
  • Page 50 Connections required to connect two controllers in parallel T6MC Controller 4 Facilities Connector Optional controllers T6MC Controller T6TR Transceiver Table 7-2 T6MC Controller to T6 Radio Connections (With Phantom Keying) 4 + Ground Facilities MARC Audio TX/RX Antenna T6MC Controller T6 Radio...
  • Page 51 Back to Disk Menu Overall Dimensions Height: 112 mm Width: 220 mm M4 wavy washer (4 off) Depth: 165 mm M4 x 10 mm panhead screw (4 off) Fig 7-3 T6MC Controller Enclosure Fixing Detail Park Air T6MC Controller...
  • Page 52 4 off M5 x 20 mm countersunk screws 36E41350200 Bottom bracket 46-00000182 2 off M4 x 8 mm panhead screws 36-45340080 2 off M4 wavy washers 36-12140000 2 off rack mount bracket 46-00000180 Fig 7-4 T6MC Rack Mount Controller Fitting Details Park Air T6MC Controller...
  • Page 53 2 off M4 x 8 mm panhead screws 36-45340080 2 off M4 wavy washers 36-12140000 Controller cover 46-00000179 10 off M3 flat washers 36-11330000 10 off M3 Nyloc nuts 36-03330000 Fig 7-5 T6MC Rack Mount Controller Enclosure Fitting Detail Park Air T6MC Controller...
  • Page 54 600R LINES FOR 2-WIRE WORKING RLB/1 EXT PTT 1N4148 1N4148 L2 TX RLB/2 L2 RX LINES FOR L1 TX 4-WIRE WORKING 1N4004 L1 RX NOTE... SHOWN IN THE RECEIVE MODE Fig 7-6 T6MC Controller Circuit Diagram Park Air T6MC Controller...
  • Page 55 Back to Disk Menu C18C15C17 INTERCOM C27 TR1 R6 D1 AW0271 ISSUE 2A C2 C4 T6 R/C Assy 24-T6MC0000/F/17 S/No 0100 Fig 7-7 T6MC Controller PCB Layout Diagram Park Air T6MC Controller...