MODEL 5318B
Level Tek II, Capacitance Level Switch
Pressing the [DN] pushbutton twice accesses
the ALARM++ procedure. The display will show:
Alarm++
XXXXX
– or –
Pressing the [DN] pushbutton three times will
access the Alarm+ procedure. The display will
show:
Alarm+
XXXXX
"XXXXX" represents the current measurement.
After a short period of time the bottom line of the
display will begin scrolling the message:
"Calibrate horizontal probe in air for high
dielectric
materials"
– or –
"Calibrate horizontal probe in air for low
dielectric
materials"
Pressing the [RT] pushbutton will enter the save
setpoint procedure. The display will show:
High SP
XXXXX
"XXXXX" represents the current measurement.
After a short period of time the top line of the
display will begin scrolling the message:
"Fill tank to HIGH setpoint, then press
RT"
Since the level is already at the desired setpoint
press [RT] to enter the save setpoint mode. The
display will show:
Save Sp-?
YES RT
Press the [RT] pushbutton to store the value or
the [LT] to abort. After pressing the [RT]
pushbutton the setpoint will be stored and the
display will return to the normal mode.
4.5.3.

ALARM - - AND ALARM -

These two modes are typically used with the
level in the vessel is above the horizontally
mounted probe. These procedures take the
current measured level and add a
predetermined offset to determine the setpoint.
The same value is stored into both setpoints.
This procedure is entered from the normal mode
by depressing the [DN] pushbutton twice,
followed by pressing the [RT] pushbutton once.
The display will show:
The bottom line will be scrolling the following
message:
"Select method of setpoint
Press the [RT] pushbutton once to enter the
methods submenu. The display will now show:
The bottom line will be scrolling the following
message:
"Scroll down to select mode, then press
RT to enter or LT to
Pressing the [DN] pushbutton four times
accesses the ALARM - procedure. The display
will show:
Pressing the [DN] pushbutton five times will
access the Alarm - - procedure. The display will
show:
"XXXXX" represents the current measurement.
After a short period of time the bottom line of the
display will begin scrolling the message:
"Calibrate submerged horizontal probe
for low dielectric
"Calibrate submerged horizontal probe
for high dielectric
Pressing the [RT] pushbutton will enter the save
setpoint procedure. The display will show:
Page 13
INSTRUCTION MANUAL
909GF295
Step 1 RT
calibration"
Exit
exit"
Alarm-
XXXXX
– or –
Alarm - -
XXXXX
materials"
– or –
materials"
Low SP
XXXXX