Download Print this page

Honeywell S-Quad Data And Installation page 14

Sensor, sounder, speech & visual alarm

Advertisement

Description & Commissioning
Compatibility
At the time of releasing this issue of data sheet the S-Quad devices were compatible for installation on the loop circuits of fire alarm
system based on panels having the following Main Controller Card/Board (MCC / MCB) and Loop Processor Card (LPC) software.
VIGILON
³ means greater than or equal to.
All S-Quad devices with VADs operate in
'Compliant mode', meets EN54 Part 23
All S-Quad devices with VADs operate in
'Non Compliant mode', that is as Visual
Indicator Devices (VIDs) meaning they
DO NOT meet EN54 Part 23.
A Vigilon System is configured using the Vigilon Commissioning Tool
NANO
All S-Cubed with VAD can be installed in a GENT Nano fire alarm system with panel card software stated below. The VADs will only
operate at a Low Power setting to meet EN54 Part 23.
³ means greater than or equal to.
All S-Cubed Mark 3 with VAD devices
A Nano System is configured using the Nano Commissioning Tool
How to check card software version
The Master Control Board MCB and Master Control Card MCC are always Card 0. There can be up to
2 loop cards installed in a Vigilon Compact Panel in slots labelled Card 1 and Card 2 on the MCB.
There can be up to 4/6 loop cards installed in a EN54 Vigilon 4/6-loop panel. The loop cards are installed in
slots labelled Card 1 to Card 4/6 on the backplane.
Press the MENU ON/OFF button.
a.
Press the F3 button to select [Info].
b.
To display a Device label: Press the F1 button to select [Display].
c.
Press the F4 button to select <etc> until [Status] appears on the display.
d.
Press the F2 button to select [Status].
e.
Press the F3 button to select [Card].
f.
Enter the Card number: For MCC/MCB this is card 0 and for the Loop processor card LPC this can be
g.
card 1,2,3, 4, 5 or 6 dependent on panel type.
Press the F2 button to select [Enter]. Notice the selected card status is displayed to include the
h.
software version number.
Support data for legacy sensor devices S4-720, S4-715, S4-710 and S4-711.
³ means greater than or equal to.
Card ->
S-Quad (introduction)
S-Quad
S-Quad supports S4-710
S-Quad supports STATE 2 &
STATE 4 Optical
S-Quad supports STATE 7 heat
8
EN panels
Vigilon
Vigilon
4 Loop
Compact
MCC
MCB
Card ->
³ 4.52
³ 4.52
³ 4.37
³ 4.37
BS panel
Vigilon
MCC
LPC
³ 3.90
³ 3.90
³ 3.90
³ 3.90
³ 3.90
³ 3.90
³ 3.94
³ 3.93
³ 3.98
³ 3.98
Vigilon
1-6 Loop
MCC
LPC
³ 4.52
³ 4.48
³ 4.37
³ 4.30
³
V1.30
Card -> MCB (Main Control Board) LP (Loop Processor)
³ 3.12
³
V3.0
EN panels
Vigilon
Vigilon
4 Loop
Compact
MCC
MCB
³ 4.21
³ 4.21
³ 4.30
³ 4.30
³ 4.30
³ 4.30
³ 4.37
³ 4.37
³4.47
³ 4.47
S-Quad
BS panel
Vigilon
4 Loop
MCC
LPC
<-Card
³ 3.90
³ 3.90
All S-Quad devices with VADs
operate in 'Non Compliant mode',
that is as Visual Indicator
Devices (VIDs) meaning they
DO NOT meet EN54 Part 23.
Nano panel
³ 1.08
Vigilon
Vigilon
Compact VA
4-6 Loop
MCB
MCC
³ 4.30
³ 4.37
³ 4.30
³ 4.37
³ 4.37
³ 4.37
³ 4.47
³ 4.47
4188-1073 issue 3_2-17_P2_S-Quad
LPC
³ 4.19
³ 4.30
³ 4.30
³ 4.35
³ 4.45

Advertisement

loading