LG WM3360H CA Series Service Manual page 27

Hide thumbs Also See for WM3360H CA Series:
Table of Contents

Advertisement

HEATING ERROR
Is
displayed?
tE ERROR
Yes
Is the connector connected to
heater disconnected or
disassembled?
Steam generator heater
Wash heater
No
Is Check heater
resistance out of range?
(12~18 Ω)
(Refer to 9-6 Heater
assembly.)
No
All manuals and user guides at all-guides.com
Is the connector connected to
thermistor disconnected or
disassembled?
Reconnect or
repair
Yes
the connector.
Is thermistor resistance
out of range?
(about 39.5 kΩ at 30
(Refer to 9-7 thermistor
assembly.)
Replace the
HEATER
Yes
ASSEMBLY.
Check the trans of water
infiltration into thermistor
terminal.
- Does the water infiltrate
[Note]
Chances that the cause occurs from the
main controller are very little.
Sensing part of the circuit (tE) consists of
only resistors and capacitors.
26
Steam generator thermistor
Wash thermistor
No
°C
)
No
thermistor terminal?
Reconnect or
Yes
repair
the connector.
Replace the
Yes
THERMISTOR
ASSEMBLY.
Replace the
Yes
THERMISTOR
ASSEMBLY.

Advertisement

Table of Contents
loading

Table of Contents