Locating Your Appliance
Note: Ventilation and air flow comes from openings in the walls and ceiling. Open floor space around the appliance
must not be considered ventilation and air flow space.
•
This unit requires combustion air and will produce exhaust gases. Install in an open-air situation with natural
ventilation and without stagnant areas.
•
Avoid installing in tight spaces and corners.
Be aware of combustibles (i.e. furniture) near appliance. Clearance is 12" when using a wind guard.
•
By definition, an outdoor space is not enclosed. Any area in which these appliances are used shall comply with
•
the structures shown below.
Locating Your Appliance – Outdoor Spaces
This appliance may be installed within the following structures:
1.
Walls on all sides (Minimum area of 96 square feet), but
with no overhead cover and at least one permanent
opening (doorway) at ground level.
3.
\
These side walls may be parallel, as in a breezeway, or at
right angles to each other.
All models can be installed safely in a screened porch area within the following guidelines:
A minimum of two (2) walls can be screened, but must be open to outside ventilation, with a minimum screen area of 64
Minimum porch area is 96sq. feet with two sides fully open.
sq. feet, and a minimum side wall height of 78" inches.
WARNING -RISK OF FIRE-
All minimum clearances must be adhered to.
2.
Within a partial enclosure that includes an overhead cover
and no more than two side walls.
4.
Within a partial enclosure that includes an overhead cover
and three side walls, as long as 30 percent or more of
the horizontal periphery of the enclosure is permanently
open.
7