Outdoor Fireplaces
The sides and top of the front face of these appliances must be covered with non-combustible materials only.
FLOOR INSTALLATION
A
COMBUSTIBLE
Clearance
A: Side wall
B: Ceiling
C: Ceiling
D: Mantel Height- Bottom
E: Mantel Height- at 10" Depth
Combustibles In Front of Unit
Top, Sides and Back of Appliance
ALCOVE
Alcove Depth- All Units
Alcove Width- OFP4336S1 & S2
Alcove Width- OFP5548S1 & S2
Alcove Width- OFP7972S1 & S2
Sides and Top of Front Faces of OFP4336 / OFP5548 / OFP7972 S1 and
S2 Fireplaces can be covered by Non-combustible materials only (i.e. brick,
stone, tile, concrete board, etc.).
OFP4336 / OFP5548 / OFP7972 S1 SHOWN
Combustible Objects on Non-Combustible Mantel
Combustible objects must not be placed on a Non-
combustible Mantel unless the mantel meets the
dimensional requirements for a Combustible Mantel.
Determine whether your mantel conforms to the
requirements of a Combustible Mantel.
CLEARANCES: OFP4336 / OFP5548 / OFP7972 (S1 & S2)
WARNING
-RISK OF FIRE-
All minimum clearances
must be adhered to.
E
D
Dimension
8-1/2"
Side of fireplace opening
61"
Bottom of Unit
35"
Top of fireplace opening
35-1/2"
Bottom of Unit
45-1/2"
Bottom of Unit
36"
Face or Facing of Fireplace
0"
Standoffs
36"
Face or Facing of Fireplace
60" = Fireplace Opening (43") plus Side wall Dim A (8-1/2") x 2
72" = Fireplace Opening (55") plus Side wall Dim A (8-1/2") x 2
96" = Fireplace Opening (79") plus Side wall Dim A (8-1/2") x 2
COMBUSTIBLE
NON-COMBUSTIBLE
NON-COMBUSTIBLE
COMBUSTIBLE
WARNING
ELEVATED INSTALLATION
COMBUSTIBLE
A
Measured From:
Mantel Dimensions are from front
face or Non-Combustible Facing
Materials covering fireplace.
C
B
ALCOVE
DEPTH
Fireplace
Opening
SIDE VIEW
15