If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
Page 5
1 YEAR PARTS AND LABOUR BENCH WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule a drop off to either an Omcan authorized service depot in the area, or to an Omcan Service warehouse to repair the equipment.
Technical Specifications Model CE-CN-WOK NG Burner BTU 95,000 Gas Type Natural Gas Number of Burners Pre-Heat Time 5 minutes Cooking Area 13” / 330mm diameter Dimensions Gas Inlet Size 3/4” / 19mm Weight 70.5 lbs. / 32 kgs. Packaging Weight 88.2 lbs.
Installation connection(s). Provide 24” clearance at the front for cleaning, maintenance, service and proper operation. AIR SUPPLY & VENTILATION • The area in front of, around and above the appliance must be kept clear to avoid any obstruction of the flow of combustion and ventilation air.
Installation be required. • The arrow shown on the bottom of the regulator body shows the gas flow direction, it should point downstream to the appliance. The red air vent cap on the top is part of the regulator and should not be removed.
Operation combustion chamber. • All appliances are adjusted and tested before leaving the factory, effectively matching them to sea level conditions. Adjustments and calibrations to assure proper operation may be necessary on installation to meet local conditions or adapt to low gas characteristics; correct possible problems caused by rough handling or vibration during shipment and are to be performed only by qualified service personnel.
Maintenance 5. Re-install burner parts in reverse order. 6. Wipe body, panel, and control knobs with mild detergent. 7. Pull catch tray from front body, wipe away residue, and clean with mild detergent. STAINLESS STEEL • All stainless steel body parts should be wiped regularly with hot soapy water during the day, and with a liquid cleaner designed for this material at the end of each day.
Page 11
Troubleshooting Yellow flame and/or black smoke. Incorrect gas. Change gas. Nozzle does not match gas Adjust nozzle diameter. requirements. Not enough air to ignite. Increase damper opening degree. Gas spikes and floats. Turn down valve flow. THE PROBLEMS MENTIONED ABOVE ARE FOR REFERENCE ONLY. IF ANY FAULT OCCURS, STOP USING THE MACHINE IMMEDIATELY AND CONTACT AN AUTHORIZED TECHNICIAN TO CHECK AND MAKE REPAIRS.
Page 13
Parts Breakdown Model CE-CN-WOK NG 47351 Item No. Description Position Item No. Description Position Item No. Description Position AI568 Top Plate and Cylinder for 47351 AI576 Burner Support Plate for 47351 AI584 Orifice NG for 47351 AI569 Input Pipe for 47351...
Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
Page 16
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.
Need help?
Do you have a question about the CE-CN-WOK NG and is the answer not in the manual?
Questions and answers