Step
14
Disconnect the
connector [S20], [S40],
[S90].
15
Release the harnesses
of [S20], [S40], [S90]
from the groove.
Disconnect the
16
terminals of the reactor.
Disconnect the relay
17
connector of the
compressor.
Removal Procedure
Procedure
[S90]
[S40]
[S20]
Reactor
Brown
Removal of Electrical Box / PCB
[S20]: electronic expansion
[S40]: overload protector
[S90]: thermistors
(R16001)
(R16002)
The colors of the harnesses
(orange or brown) do not
matter to the position of the
connector.
Orange
(R14508)
(R16003)
Points
valve coil
9