Product Specifications - Promation Engineering P2 DC Series Installation & Operation Manual

Table of Contents

Advertisement

Product Specifications

100%
75%
Proportional
50%
On/Off/Jog
25%
50°F
75°F
100°F
10°C
24°C
38°C
Ambient Temperature
Introduction
This document provides necessary information for set-up, calibration, testing and use of the P Series quarter-turn
electric actuators stated on the cover page. Each unit is shipped from the factory with initial calibration of mechanical
stops, cams and switches completed for 0-90 degree operation. However, these are general settings and serve as
a starting point for proper calibration of the actuator in its real-world application.
Safety
Safety is a basic factor any time you maintain and operate mechanical equipment. Appropriate handling methods
and proper use of tools and clothes can help prevent serious accidents -- accidents which can cause injuries
to you or a fellow worker. This manual was created to enable a trained user to install, adjust and troubleshoot
your ProMation actuator.
Only competent and trained personnel should install, maintain and operate ProMation actuators. Any work
related to this actuator must be carried out in accordance with this manual and related codes and regulations.
Local workplace health and safety rules should always be followed.
Duty cycle
Duty cycle is the percent of time that an actuator spends running as a fraction of the total time. Duty Cycle is
directly related to heat; excessively repositioning an actuator typically results in motor overheating which can
cause permanent damage and/or reduced service life.
Duty cycle can be calculated as follows:
(example P2 series actuator running 3 seconds ON and 30 seconds OFF)
Runtime = 3s, Total time = 3s + 30s = 33s, therefore this duty cycle would be 9% (3/33)
Additionally, ProMation P series actuators are designed for a maximum of 1200 starts per hour (one start every
3 seconds maximum).
Actuator Specifications
Torque "lb/Nm
Supply Voltage
Max Inrush Current
Running Current
Motor
Runtime (90°@60Hz/vdc)
Runtime (90
Duty Cycle
Motor Starts
Weight
Mechanical Connections
Electrical Entry
Electrical Terminations
Environmental Rating
Manual Override
Control
Actuator Case Material
Motor Protection
Ambient Temperature
Operating Range
125°F
150°F
52°C
65°C
Page 2 of 14 P2/3 12VDC Proportional Series
P2
800"lbs/90Nm
12vdc
5.2A
3.4A
15 sec
@50Hz)
O
Aluminum Alloy, Powder coated
230°F/110°C Thermal F* Class
*Totally Enclosed Non-Ventilated Motors
P3
1335"lbs/150Nm
24vdc
12vdc
24vdc
4.5A
4.9A
5.0A
2.2A
4.4A
2.4A
DC Brush Type
22 sec
--
--
75%
1200 per hour
26lbs/12kg
ISO5211 F07 8pt 22mm
(2) 3/4" NPT
12-18ga
NEMA 4/4X
5" Handwheel
Proportional
-22°F to +125°F
-30°C to +52°C

Advertisement

Table of Contents
loading