First Lighting; Operation - Supra PERSEE Instructions For Installation And Use Manual

Table of Contents

Advertisement

- This wood stove is designed to operate with the door closed. The
door must remain closed at all times except when loading.
- Leave a space of at least 5 cm between the bottom of the stovebox
and the top of the logs.
- To avoid any risk of burns, do not touch the appliance and use the
glove to operate the different controls.
- The heat radiation through the glass requires that any material that
may be damaged or affected by the heat should be removed (furniture,
wallpaper, woodwork, etc.). A distance of 2 m is sufficient to avoid
any risk.
3.1.
FUEL
3.1.1. Wood
Burn only firewood, in log form, air-dried (2 to 3 years storage in a well venti-
lated, sheltered place) with 15 to 20 % humidity maximum.
- Choose hard deciduous woods if possible (birch, hornbeam, beech...),
- Avoid soft woods (lime, chestnut, willow, poplar)
- Never use coniferous woods (pine, fir...) for permanent use, or treated
used woods (railway sleepers, joiners' cut-offs...) and domestic waste
(vegetable materials or plastics).
- Never make a blaze with armfuls of kindling, crates, small logs or vine
shoots which can cause sudden overheating.
3.1.2. Lignite
Used in normal operation (daytime) or for slow burning (night use), alone
or with wood, the lignite briquette is an economical fuel.
Place the briquettes in a layer over a bed of embers, covering only the
surface of the grate.
W
ARNING! The use, even occasionally, of coal or any coal
W
ARNING!
derivative is strictly prohibited. This appliance must not be used
to burn domestic waste!
Commande
Air de vitre
+
3.1 COMMANDES
(SCHÉMA INDICATIF)
W
ARNING
W
ARNING
-
PERSEE
3. USE
3.2.
DRAUGHT
The draught in the smoke flue when hot must never exceed 20 Pa. If the
draught is greater, install a draught adapter. Consult your dealer in order to
have the draught measured when the stove is installed. The presence of a
controlled mechanical ventilation system may have an effect on the draught
value and even reverse it. For this reason, the extractor must be in operation
when the draught is measured.
3.3.

FIRST LIGHTING

Remove the sticky labels (except signage), any packaging cardboard and
ensure that there is nothing in the ashbox.
Start with a small fire then, in stages, increase the load. This progressive
rise in the temperature allows the materials to dilate slowly and stabilise.
Tab. 3.1
PERSEE
Grid air
Glass air
Smoke and a smell will be given off at first (due to the presentation paint)
but this will fade in time. Proceed in this way for several days before beginning
normal use. Open the windows during the first few times.
During the first heating, check the draught against the table of technical
characteristics, and adjust the draft regulator if necessary.
.
3.4.

OPERATION

3.4.1. Lighting
Spread some crumpled paper on the bottom of the stove, place some kindling
on top and some small spit logs. Position the controls as shown in Table
Commande
Air de combustion
-
+
GB 5/8
lighting
nominal
open
open
open
open
PERSEE
mini
closed
1/2 closed
40730-06-16