1.
TECHNICAL
1.
TECHNICAL
STOVE
Category of stove
(1)
Rated heating output
Operation with door closed only
Type of connection
Average temperature of smoke with door closed
Efficiency
CO rate (13% O 2 )
Fuels
Log size
Nominal/max. hourly load
Reloading intervalt
Alternative fuel
Prohibited fuels
Mass flow of smoke
Nominal diameter of smoke outlet
Characteristics of smoke flue
Minimum dimensions of chimney block
Min.Ø of tubing or insulated metal flue
Min. height of flue above fire
Ventilation of room
Draught ( (10 Pa = 1 mm CE)
Nominal speed
Reduced speed (min. admissible)
Max. admissible
Net / gross weight
Manufacturer's plate
Accessories supplied
Insulated glove
- This appliance is intended to burn wood, on no account may it be used as an incinerator or to burn liquid fuels, coal or derivatives.
- All local or national regulations, as well as the European standards
using the appliance.
- The heating appliance is hot when in use, particularly the glazed front. It remains hot for a long time, even if the flames are no longer visible. Take
precautions to avoid all contact with the appliance (young children in particular).
- Before accessing the electrical connection parts, all the power circuits must be switched off.
- This appliance must be installed in accordance with the specifications of the standards
mended.
- The instructions in this booklet must be followed scrupulously. Keep these instructions in a safe place.
- The manufacturer's liability is limited to the supply of the appliance. It may not be held liable in the event of any failure to respect these instructions.
- The following are especially prohibited:
- The installation of materials that may be affected or damaged by the heat (furniture, wallpaper, woodwork) too close to the fire.
- The installation of any heat regenerator other than those recommended by the manufacturer.
- The use of any fuel other than natural wood and lignite.
- Any modification to the appliance or the installation not provided for by the manufacturer, which would release it from its liability and cancel the warranty.
Use exclusively spare parts recommended by the manufacturer.
- Any failure to comply with these indications is entirely the responsibility of the person who carries out the work and assembles the fire.
Your chimney "draws well", but you probably do not know the degree of negative pressure. The negative pressure or draught in a chimney
is measured in Pascals (Pa). All inserts, closed fires and fires are designed, optimised and built according to French standards NF 13229
(or NF 13240) to operate connected to a chimney duct whose nominal draught is 12 Pa. Very often (more than one chimney in two), the
draught is too strong (over 20 Pa). This can be due to the chimney being too high or an installation with tubing. The fires then operate in
abnormal conditions, leading to:
- Excessive wood consumption: this may be three times more than for a fire operating with a draught of 12 Pa.
- A fire that does not last, burning much too fast and giving off very little heat.
- The rapid and irreparable deterioration of the fire (cracks in the cast iron hearth plate or firebricks).
- The invalidation of the guarantee.
To avoid all these problems, there is only one solution.
Have your chimney's draught checked (with the fire in operation) by a professional and if it is over 20 Pa, install a draught regulator on the
fire's connection pipe.
CHARACTERISTICS
CHARACTERISTICS
all others, including coal and derivatives

- IMPORTANT ASSEMBLY INFORMATION -

PERSEE
PERSEE
Continuous
8 kW
horizontal
307 °C
75,7 %
0,25 %
firewood
33 cm max
1,5 kg
1 h
lignite
4,9 g/s
120/125 mm
20 x 20 cm
125 mm
4 m
1 dm²
12 Pa ± 2 Pa
6 Pa ± 1 Pa
20 Pa
95/105 kg
behind the ashbox
- WARNING -
(1)
must be respected as well as the European standards(1) when installing and
(1)
GB 3/8
in force. Installation by a qualified professional is recom-
40730-06-16