5.1.2 Assembling the surface-mounted variant
www.ces.eu
1. Slide the surface-mounted frame off the reader.
The connecting cable is fed in either from above, from below or directly
from the wall. Pull out the relevant cable point.
2. Screw the surface-mounted frame onto the wall.
3. Secure the tear-off tab for tamper detection with a screw.
4. Remove the cover cap from the reader.
5. Remove the connection terminal.
6. Set DIP switch 5 to ON.
7. Use DIP switches 1-4 to set the reader addresses for the connected units.
DIP
Function
1 – 4
Setting the reader address
5
Baud rate (always ON)
6
Bus terminating resistor for RS485