Download Print this page

Cooper Lighting Solutions Fail Safe Narrow Installation Instructions Manual

Advertisement

Available languages

Available languages

Quick Links

IB51915121
Installation Instructions – Fail Safe Narrow (FSN)
Instructions d'installation – Fail Safe Narrow (FSN)
Instrucciones de instalación – Fail Safe Narrow (FSN)
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product
must be performed by a qualified electrician. This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and operation of the product and hazards
involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any
maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Minimum 90°C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Must be very careful if power tools are used to install the fixture. Uncontrolled torque setting may lead to
thread/gasket damage or lens breakage.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may
arise from the improper, careless, or negligent installation, handling or use of this product.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
NOTICE: These instructions do not claim to cover all details or variations in the equipment, procedure, or process
described, or to provide directions for meeting every possible contingency during installation, operation or maintenance.
When additional information is desired to satisfy a problem not covered sufficiently for user's purpose, please contact your
nearest representative.
NOTICE: Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation
section.
NOTICE: Fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
GENERAL: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention
of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.
WARNING
Fail-Safe

Advertisement

loading
Need help?

Need help?

Do you have a question about the Fail Safe Narrow and is the answer not in the manual?

Questions and answers

Summary of Contents for Cooper Lighting Solutions Fail Safe Narrow

  • Page 1 Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Page 2 Installation Instructions – Fail Safe Narrow (FSN) For T-Grid Mounting: Grid clips are provided for additional retention to ceiling system. Orient tabs on back of fixture over T-GRID by Turn off the power at the main fuse/breaker box. bending tabs up 90 degrees perpendicular to back of fixture.
  • Page 3 Installation Instructions – Fail Safe Narrow (FSN) This fixture is compatible with 0-10V dimming. With fixture powered on, use the lumen switch and CCT ote: If installing dimming wires follow your dimmer switch (if equipped) to adjust the fixture to the desired instructions for wiring to the violet (Dim +) and pink lumen level and CCT (Figure 7).
  • Page 4 Installation Instructions – Fail Safe Narrow (FSN) For IP66/65 Applications: With the fixture positioned in the grid, press included L-Bracket to the back plate of the fixture and fasten it to the grid using included self-drilling screw. Reference images below for the location of the L-Brackets for IP65/IP66 applications by size.
  • Page 5 La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et de dommages matériels. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit.
  • Page 6 Instructions d’installation – Fail Safe Narrow (FSN) Passez le luminaire dans la grille à un angle de Si un soutien supplémentaire est néces- emarque: saire, utilisez le câble pour supporter le luminaire à la 45 degrés puis déposez-le sur la grille (Figure 2).
  • Page 7 Instructions d’installation – Fail Safe Narrow (FSN) Groupez tous les fils et les capuchons de connexion 10. Une fois que le niveau d’intensité de lumens et le dans la boîte de jonction du luminaire, réinstallez la TC souhaités ont été sélectionnés, fixez solidement le couvercle de l’interrupteur fourni à...
  • Page 8 El incumplimiento de estas instrucciones puede ocasionar la muerte, lesiones corporales graves y daños a la propiedad. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan surgir por la instalación, manipulación o uso inadecuado, descuidado o negligente de este producto.
  • Page 9 Instrucciones de instalación – Fail Safe Narrow (FSN) Pase la luminaria a través de la grilla en un ángulo y Si desea un soporte adicional, utilice el cable ota: luego colóquela en dicha grilla. (Figura 2) para sujetar la luminaria a la viga de apoyo correspondiente arriba de dicha luminaria por medio de los agujeros circulares en las lengüetas de los...
  • Page 10 Instrucciones de instalación – Fail Safe Narrow (FSN) Coloque todos los cables y tuercas para cables en la 10. Una vez que se han seleccionado el nivel de lúmenes caja de derivación de la luminaria, vuelva a colocar la deseado y el CCT, fije la cubierta del interruptor provista placa de acceso eléctrico y apriete el tornillo...
  • Page 11 Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Canada Sales Cooper Lighting Solutions is a registered 5925 McLaughlin Road trademark. All trademarks are property Mississauga, Ontario L5R 1B8 of their respective owners. Product availability, specifications,...