Prevention Of Electro-Static Discharge - Panasonic PV-V4524S Service Manual

Video cassette recorder
Table of Contents

Advertisement

equipment such as screwheads, connectors, control shafts, etc. When
the exposed metallic part has a return path to thechassis, the reading
should be between 1 M
not have a return path to the chassis, the reading must be infinity.
LEAKAGE CURRENT HOT CHECK / (See figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation
transformer for this check.
2. Connect a 1.5 k
between each exposed metallic part on the set and a good earth
ground, as shown in figure 1.
3. Use an AC voltmeter, with 1 k
potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each
point.
5. Reverse the AC plug in the AC outlet and repeat each of the above
measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent) may be
used to make the hot checks. Leakage current must not exceed 1/2
mA. In case a measurement is outside of the limits specified, there is a
possibility of a shock hazard, andthe equipment should be repaired
and rechecked before it is returned to the customer.

2. PREVENTION OF ELECTRO-STATIC DISCHARGE

(ESD) TO ELECTROSTATICALLY SENSITIVE (ES)
DEVICES
and 5.2 M
, 10 W resistor, in parallel with a 0.15
/V or more sensitivity, to measure the
Figure 1
. When the exposed metal does
3
F capacitor,